RT-PCR is the gold standard for diagnosis of COVID-19. All RT-PCR kits are based on RNA extraction from the clinical sample. There was a sudden increase in demand of these kits, both RNA extraction and COVID-19 RT-PCR kits during the pandemic. This sudden spurt in global demand created a situation of shortage of consumables, especially the RNA extraction kits. Hence, this study was carried out to evaluate and compare COVID-19 RT-PCR without RNA extraction step using buffer R3. Sensitivity, specificity and accuracy of RT-PCR kit without RNA extraction were 89.16 %, 100% and 89.6% respectively. This approach saved more than 50 % time compared to the RT-PCR kit with RNA extraction approach allowing enhanced daily sample processing capability. RT-PCR kit without RNA extraction help in managing a greater number of samples, reduces cost and turnaround time.