Carbapenem resistance is a serious public health threat, causing numerous deaths annually primarily due to healthcare-associated infections. To face this menace, surveillance programs in high-risk patients are becoming a widespread practice. Here we report the performance of the combined use of a recently approved commercial multiplex real-time PCR assay (REALQUALITY Carba-Screen kit) with conventional phenotypic screening. In this three-month study, 479 rectal swabs from 309 patients across high-risk units were evaluated by combining the two approaches. Although the molecular assay showed a higher positivity rate than phenotypic screening (7.1% vs. 5%), it should be noted that the molecular method alone would have missed eight carbapenem-resistant isolates, while using only phenotypic screening would not have detected sixteen isolates. This demonstrates the complementary strengths of each method. Our study confirms the need for a combined approach to maximize the possible clinical impact of this kind of screening, ensuring a more comprehensive detection of resistant strains.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11311838PMC
http://dx.doi.org/10.3390/diagnostics14151599DOI Listing

Publication Analysis

Top Keywords

phenotypic screening
16
assay realquality
8
realquality carba-screen
8
screening
5
combined phenotypic
4
screening novel
4
novel commercial
4
commercial assay
4
carba-screen rapid
4
rapid molecular
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?