Flow-Field Inference for Turbulent Exhale Flow Measurement.

Diagnostics (Basel)

Department of Computer Science and Engineering, University of Colorado Denver, Denver, CO 80204, USA.

Published: July 2024

Background: Vision-based pulmonary diagnostics present a unique approach for tracking and measuring natural breathing behaviors through remote imaging. While many existing methods correlate chest and diaphragm movements to respiratory behavior, we look at how the direct visualization of thermal CO exhale flow patterns can be tracked to directly measure expiratory flow.

Methods: In this work, we present a novel method for isolating and extracting turbulent exhale flow signals from thermal image sequences through flow-field prediction and optical flow measurement. The objective of this work is to introduce a respiratory diagnostic tool that can be used to capture and quantify natural breathing, to identify and measure respiratory metrics such as breathing rate, flow, and volume. One of the primary contributions of this work is a method for capturing and measuring natural exhale behaviors that describe individualized pulmonary traits. By monitoring subtle individualized respiratory traits, we can perform secondary analysis to identify unique personalized signatures and abnormalities to gain insight into pulmonary function. In our study, we perform data acquisition within a clinical setting to train an inference model (FieldNet) that predicts flow-fields to quantify observed exhale behaviors over time.

Results: Expiratory flow measurements capturing individualized flow signatures from our initial cohort demonstrate how the proposed flow field model can be used to isolate and analyze turbulent exhale behaviors and measure anomalous behavior.

Conclusions: Our results illustrate that detailed spatial flow analysis can contribute to unique signatures for identifying patient specific natural breathing behaviors and abnormality detection. This provides the first-step towards a non-contact respiratory technology that directly captures effort-independent behaviors based on the direct measurement of imaged CO exhaled airflow patterns.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11311330PMC
http://dx.doi.org/10.3390/diagnostics14151596DOI Listing

Publication Analysis

Top Keywords

turbulent exhale
12
exhale flow
12
natural breathing
12
exhale behaviors
12
flow
9
flow measurement
8
measuring natural
8
breathing behaviors
8
exhale
6
behaviors
6

Similar Publications

Nanocarrier-based dry powders for lung disease treatment are crucial, with in vitro and in silico research being pivotal to their success. This study introduces a method for creating Tiotropium-bromide liposomal inhalation dry powder, termed "Trojan-particles," utilizing thin-film hydration and spray-drying with lactose-arginine carriers. Encapsulating tiotropium-bromide in nanoliposomes enhances lung treatment via liposomes' unique features.

View Article and Find Full Text PDF

Optimal human respiratory simulation for exhaled gas based on CFD method.

PLoS One

November 2024

Beijing Key Laboratory of Green Built Environment and Energy Efficient Technology, Beijing University of Technology, Beijing, China.

Human breathing is crucial for studying indoor environments and human health. Computational Fluid Dynamics (CFD) is a key tool for simulating human respiration. To enhance the accuracy of CFD simulations and reduce computation time, a new simulation strategy for human respiration is proposed in this paper.

View Article and Find Full Text PDF

Flow-Field Inference for Turbulent Exhale Flow Measurement.

Diagnostics (Basel)

July 2024

Department of Computer Science and Engineering, University of Colorado Denver, Denver, CO 80204, USA.

Background: Vision-based pulmonary diagnostics present a unique approach for tracking and measuring natural breathing behaviors through remote imaging. While many existing methods correlate chest and diaphragm movements to respiratory behavior, we look at how the direct visualization of thermal CO exhale flow patterns can be tracked to directly measure expiratory flow.

Methods: In this work, we present a novel method for isolating and extracting turbulent exhale flow signals from thermal image sequences through flow-field prediction and optical flow measurement.

View Article and Find Full Text PDF

This work, in a pioneering approach, attempts to build a biometric system that works purely based on the fluid mechanics governing exhaled breath. We test the hypothesis that the structure of turbulence in exhaled human breath can be exploited to build biometric algorithms. This work relies on the idea that the extrathoracic airway is unique for every individual, making the exhaled breath a biomarker.

View Article and Find Full Text PDF

Three dimensional analysis of the exhalation flow in the proximity of the mouth.

Heliyon

February 2024

Dept. of the Built Environment, Aalborg Universitet, Thomas Manns Vej 23 9220 Aalborg Øst, Denmark.

The human exhalation flow is characterized in this work from the three-dimensional velocimetry results obtained by using the stereo particle image velocimetry (SPIV) measurement technique on the flow emitted from a realistic airway model. For this purpose, the transient exhalation flow through the mouth of a person performing two different breaths corresponding to two metabolic rates, standing relaxed (SR) and walking active (WA), is emulated and studied. To reproduce the flow realistically, a detailed three-dimensional model obtained from computed tomography measurements on real subjects is used.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!