Exploration of novel solid-phase extraction modes for analysis of multiclass emerging contaminants.

Anal Chim Acta

University of Ljubljana, Faculty of Chemistry and Chemical Technology, Večna pot 113, SI-1000, Ljubljana, Slovenia.

Published: August 2024

Solid-phase extraction (SPE) has gained an essential role in environmental analytical chemistry. Classic off-line SPE coupled with LC-MS/MS systems creates powerful analytical procedures for ultratrace analysis of contaminants of emerging concern (CECs) in water. But, being associated with tedious work and large consumption of materials, alternative SPE modes are becoming interesting. As so, the study focuses on development, evaluation, and overall comparison of established and novel SPE modes. Off-line SPE, dispersive micro SPE (DMSPE), and 'fast' single-pump on-line SPE were explored, using commercially available sorbents. Their efficiency was evaluated on their performance in water analysis of 20 multiclass CECs. Hydrophilic-lipophilic sorbent and mixture of C18/C8 sorbents were the best choice for off-line and DMSPE, respectively. All optimized SPE modes coupled with UHPLC-MS/MS reached environmentally-relevant limits of detection (LODs 0.1-12 ng L), acceptable repeatability (<20 % RSD), and exhibited less than ±30 % matrix effects in real river water sample. Among all, on-line SPE showed a potential to fully replace the well-established off-line SPE and even improve analytical performance. This was due to the best repeatability (<10 % RSD), automatization, simplicity, the highest multiplexing capacity, as well as comparable LODs of <2 ng L. DMSPE is, on the other hand, the most innovative and could be seen as a quick and green alternative to off-line SPE for determination of semi-to-nonpolar CECs, but within sub-10 ng L range. Overall, the study shows workflow for the exploration of important and promising sample pretreatment techniques in water analysis. Comparison of the developed three SPE-UHPLC-MS/MS methods suggests that alternative SPE modes can compete with the well-established off-line SPE and can even improve the analysis quality if properly applied.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.aca.2024.342955DOI Listing

Publication Analysis

Top Keywords

spe modes
12
solid-phase extraction
8
analysis multiclass
8
spe
8
off-line spe
8
exploration novel
4
novel solid-phase
4
modes
4
extraction modes
4
modes analysis
4

Similar Publications

Comparison of Sample Preparation and Detection Methods for the Quantification of Synthetic Musk Compounds (SMCs) in Carp Fish Samples.

Molecules

November 2024

Metropolitan Seoul Center, Korea Basic Science Institute, University-Industry Cooperation Building, 150 Bugahyeon-ro, Seodaemun-gu, Seoul 03759, Republic of Korea.

This study deals with the separation and detection methods for 12 synthetic musk compounds (SMCs), which are some of the emerging contaminants in fish samples, are widely present in environmental media, and can be considered serious risks due to their harmful effects. For the separation of co-extracted substances and the target SMCs in fish samples after ultrasonic extraction, four solid-phase extraction (SPE) sorbents were investigated. The recoveries of SMCs from 10 mL of eluent, as optimized by the elution profile, were within the acceptable range of 80-120% in all SPE types, and it was found that nitro musk and polycyclic musk compounds were separated more clearly in Florisil SPE than others (Aminopropyl, Alumina-N, PSA).

View Article and Find Full Text PDF

Molecular insight into algae-derived dissolved organic matters via Fourier-transform ion cyclotron resonance mass spectrometry: Effects of pretreatment methods and electrospray ionization modes.

J Hazard Mater

December 2024

State Key Laboratory of Environment Criteria and Risk Assessment, Chinese Research Academy of Environmental Sciences, Beijing 100012, China. Electronic address:

The release of algae-derived dissolved organic matter (ADOM) significantly increased in serious eutrophication waters, posing great threats to drinking water safety. Thus, the molecular composition decipherment is urgently in need. However, due to unsatisfactory pretreatment and ionization effects, the application of Fourier-transform ion cyclotron resonance mass spectrometry (FT-ICR-MS) on ADOM was limited.

View Article and Find Full Text PDF

Concerns over the emergence of steroid hormones as pollutants in water have grown. Steroid hormone compounds present challenges in the simultaneous detection of total residual hormones owing to their analogous structures and diverse types. In this study, we established a rapid and high-throughput continuous online method based on solid phase extraction (SPE) coupled with ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) for the simultaneous determination of 61 hormone components, including 48 glucocorticoids, 1 mineralocorticoid, 4 androgens, and 8 progesterones, in water.

View Article and Find Full Text PDF

Exploration of novel solid-phase extraction modes for analysis of multiclass emerging contaminants.

Anal Chim Acta

August 2024

University of Ljubljana, Faculty of Chemistry and Chemical Technology, Večna pot 113, SI-1000, Ljubljana, Slovenia.

Solid-phase extraction (SPE) has gained an essential role in environmental analytical chemistry. Classic off-line SPE coupled with LC-MS/MS systems creates powerful analytical procedures for ultratrace analysis of contaminants of emerging concern (CECs) in water. But, being associated with tedious work and large consumption of materials, alternative SPE modes are becoming interesting.

View Article and Find Full Text PDF
Article Synopsis
  • The study focuses on developing a sensitive method to analyze bisphenol analogues (BPs), a group of chemicals that disrupt endocrine functions, in human urine samples.
  • The process involves thawing urine, digesting it with an enzyme, purifying it using solid-phase extraction, and analyzing it with advanced liquid chromatography and mass spectrometry techniques.
  • Results showed that the method had very low detection limits, high recovery rates, and reliable precision, making it effective for accurately identifying BPs without false positives.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!