In computed tomography (CT), organ dose modulation (ODM) reduces radiation exposure from the anterior side to reduce radiation dose received by the radiosensitive organs located anteriorly. We investigated the effects of ODM applied to a part of the scan range on radiation dose in body CT. The thorax and thoraco-abdominopelvic region of an anthropomorphic whole-body phantom were imaged with and without ODM. ODM was applied to various regions, and the tube current modulation curves were compared. Additionally, the dose indices were compared with and without ODM in thoracic and thoraco-abdominopelvic CTs in 800 patients. ODM was applied to the thyroid in male patients and to the thyroid and breast in female patients. In phantom imaging of the thorax, the application of ODM below the scan range decreased the tube current, and that to the breast showed a further decrease. Decreased tube current was also observed in phantom imaging of the thoraco-abdominopelvic regions with ODM below the scan range, and the application of ODM to the whole scan range, thyroid, breast, and both thyroid and breast further reduced the tube current in the region to which ODM was applied. In patient imaging, the dose indices were significantly lower with ODM than without ODM, regardless of the scan range or sex. The absolute reduction in dose-length product was larger for thoraco-abdominopelvic CT (male, 43.2 mGy cm; female, 59.7 mGy cm) than for thoracic CT (male, 30.8 mGy cm; female, 37.6 mGy cm) in both sexes, indicating dose reduction in the abdominopelvic region to which ODM was not applied. In conclusion, The application of ODM in body CT reduces radiation dose not only in the region to which ODM is applied but also outside the region. In radiation dose management, it should be considered that even ODM applied to a limited region affects the dose indices.

Download full-text PDF

Source
http://dx.doi.org/10.1088/1361-6498/ad6d76DOI Listing

Publication Analysis

Top Keywords

odm applied
28
scan range
24
radiation dose
20
odm
16
tube current
16
odm scan
16
dose indices
12
thyroid breast
12
application odm
12
region odm
12

Similar Publications

Digital Twins for Clinical and Operational Decision-Making: Scoping Review.

J Med Internet Res

January 2025

Australian e-Health Research Centre, Commonwealth Scientific and Industrial Research Organisation, Brisbane, Australia.

Background: The health care industry must align with new digital technologies to respond to existing and new challenges. Digital twins (DTs) are an emerging technology for digital transformation and applied intelligence that is rapidly attracting attention. DTs are virtual representations of products, systems, or processes that interact bidirectionally in real time with their actual counterparts.

View Article and Find Full Text PDF

In computed tomography (CT), organ dose modulation (ODM) reduces radiation exposure from the anterior side to reduce radiation dose received by the radiosensitive organs located anteriorly. We investigated the effects of ODM applied to a part of the scan range on radiation dose in body CT. The thorax and thoraco-abdominopelvic region of an anthropomorphic whole-body phantom were imaged with and without ODM.

View Article and Find Full Text PDF

Against the backdrop of global warming, intensifying regional conflicts, deglobalization, and the spread of diseases, global food security is facing severe challenges. Studying the food security situation in China and the United States in depth can provide practical experience for formulating food security policies for countries around the world and promoting global food security governance. On the basis of a meticulous review of the evolving connotations of food security, this study adopts six dimensions-quantity security, quality security, circulation security, economic security, ecological resource security, and policy security-as breakthrough points to construct a framework consisting of food security evaluation indicator system comprising 29 specific indicators.

View Article and Find Full Text PDF

Background: Oil palm ( Jacq.) is one of the major oil-producing crops. Improving the quality and increasing the production yield of oil palm have been the primary focuses of both conventional and modern breeding approaches.

View Article and Find Full Text PDF

The relationship between externally applied force and intraocular pressure was determined using an ex-vivo porcine eye model (N=9). Eyes were indented through the sclera with a convex ophthalmodynamometry head (ODM). Intraocular pressure and ophthalmodynamometric force were simultaneously recorded to establish a calibration curve of this indenter head.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!