A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Investigation of hand tremor suppression by a customized passive surgical support robot during internal limiting membrane peeling. | LitMetric

Purpose: To construct a quantitative evaluation system for hand tremor during internal limiting membrane (ILM) peeling and investigate changes in hand tremor attributable to the use of the customized passive surgical support robot.

Methods: This analytical and experimental study developed a hand tremor evaluation system that synchronizes three elements: surgical microscope images, an artificial eye module with a force sensor to simulate ILM peeling, and microforceps with an inertial measurement unit. Two surgeons used this system to measure hand tremor during ILM peeling with and without the robot.

Results: The horizontal, vertical, and combined vertical and horizontal components of hand tremor were 8.1 ± 6.1, 1.7 ± 1.8, and 8.5 ± 6.2 mG, respectively, in the no robot group. These components decreased to 7.2 ± 6.0, 1.5 ± 1.7, and 7.5 ± 6.1 mG, respectively, in the robot group. In particular, hand tremor was significantly suppressed by 11.9% for the horizontal component using the robot (p = 0.0006).

Conclusion: The newly constructed system helps to quantitatively evaluate hand tremor during ILM peeling. The customized passive surgical support robot enables to decrease hand tremor during ILM peeling.

Download full-text PDF

Source
http://dx.doi.org/10.1097/IAE.0000000000004226DOI Listing

Publication Analysis

Top Keywords

hand tremor
36
ilm peeling
20
customized passive
12
passive surgical
12
surgical support
12
tremor ilm
12
tremor
9
support robot
8
internal limiting
8
limiting membrane
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!