Aim: To assess the roughness and hydrophilicity of nine types of dental implant surfaces, while also examining the presence of contaminants carbon and oxygen on these surfaces. Furthermore, the study investigated potential correlations between these characteristics across the analyzed surfaces. Materials and Methods: The surfaces analyzed were as follows: MI: machined (turned), Implacil implant; TOI: blasted with titanium oxide, Implacil implant; TOAEI: blasted with titanium oxide and acid-etched, Implacil implant; ZAED: blasted with zirconia and acid-etched, DSP implant; CPD: coated with calcium phosphate, DSP implant; XD: subjected to an experimental treatment (patent pending), DSP implant; DAEHAS: double acid-etched and activated with hydroxyapatite nano-crystals, SIN implant; DAES: double acid-etched, SIN implant; and AMP: untreated surface of the Plenum implant, produced by additive manufacturing. Four and five disc-shaped specimens were used in the hydrophilicity and roughness assessments, respectively. Roughness was evaluated by optical profilometry and scanning electron microscopy; hydrophilicity was determined using the sessile-drop technique; and the chemical analysis was performed using X-ray photoelectron spectroscopy. The Kruskal- Wallis, Mann-Whitney, and Spearman correlation tests were employed to analyze the data (p < 0.10). Results: Significant differences were observed among the analyzed surfaces in terms of both roughness and hydrophilicity (p < 0.001). The surface exhibiting the highest roughness was AMP, whereas the greatest hydrophilicity was exhibited by CPD. Correlations between roughness and hydrophobicity were observed for MI (r = 0.936, p = 0.009), ZAED (r = 0.957, p = 0.004), and DAES (r = 0.964, p = 0.005). The carbon concentration observed on the CPD surface was lower than that observed on the other surfaces, whereas the oxygen concentrations were similar. No correlations were observed between the presence of contaminants and the roughness or hydrophilicity characteristics. Conclusion: Roughness and hydrophilicity values exhibited considerable variation among the tested surfaces. Aside from the CPD surface, comparable concentrations of carbon and oxygen were detected. Although correlations between roughness and hydrophilicity were observed only for the ZAED, DAES, and MI surfaces, these correlations were inadequate to establish a causal relationship between the two surface characteristics.

Download full-text PDF

Source
http://dx.doi.org/10.11607/jomi.11045DOI Listing

Publication Analysis

Top Keywords

roughness hydrophilicity
20
implacil implant
12
dsp implant
12
implant
11
surfaces
9
roughness
9
implant surfaces
8
hydrophilicity
8
presence contaminants
8
carbon oxygen
8

Similar Publications

AISI 316L stainless steel is extensively used in various fields, including medicine. In this study, in order to improve antibacterial properties, reduce elastic modulus, increase hydrophilicity and delay corrosion on the surface of AISI 316L stainless steel pieces for biomedical applications, zinc and magnesium elements were used for coating. Zn monolayer, Zn-Mg bilayer, and Zn-Mg-Zn triple coatings were deposited on AISI 316L substrates using the thermal evaporation method.

View Article and Find Full Text PDF

A Wenzel Interfaces Design for Homogeneous Solute Distribution Obtains Efficient and Stable Perovskite Solar Cells.

Adv Mater

January 2025

College of Chemistry and Chemical Engineering/Film Energy Chemistry for Jiangxi Provincial Key Laboratory (FEC), Nanchang University, 999 Xuefu Avenue, Nanchang, 330031, China.

The coffee-ring effect, caused by uneven deposition of colloidal particles in perovskite precursor solutions, leads to poor uniformity in perovskite films prepared through large-area printing. In this work, the surface of SnO is roughened to construct a Wenzel model, successfully achieving a super-hydrophilic interface. This modification significantly accelerates the spreading of the perovskite precursor solution, reducing the response delay time of perovskite colloidal particles during the printing process.

View Article and Find Full Text PDF

Design and Characterization of Novel Polymeric Hydrogels with Protein Carriers for Biomedical Use.

Int J Mol Sci

December 2024

Department of Materials Engineering, Faculty of Materials Engineering and Physics, Cracow University of Technology, 37 Jana Pawla II Av., 31-864 Krakow, Poland.

Hydrogels are three-dimensional polymeric matrices capable of absorbing significant amounts of water or biological fluids, making them promising candidates for biomedical applications such as drug delivery and wound healing. In this study, novel hydrogels were synthesized using a photopolymerization method and modified with cisplatin-loaded protein carriers, as well as natural extracts of nettle () and chamomile ( L.).

View Article and Find Full Text PDF

The present study aims to analyze the thermal regulation of the Ce/Ce ratio on the nanonetwork titania layer over the titanium (Ti) surface developed by the alkali-mediated surface modification approach. The effect of sequential heat treatment from 200 to 800 °C was evaluated for its surface characteristics such as morphology, phase formation, roughness, hardness, hydrophilicity, etc. Surface oxidation by temperatures up to 600 °C demonstrated a progressive increase in the Ce (CeO) content with a rutile TiO network layer over the Ti surface.

View Article and Find Full Text PDF

To analyze hydration effects on macromolecular diffusion, the friction coefficients of macromolecules were examined using molecular dynamics simulations with an all-atom model. In the present study, a method was introduced to decompose the molecular friction coefficient into the contributions for each site on the macromolecule. The method was applied to several fullerenols in ambient water.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!