Effective internal fixation with pedicle screw is a key factor in the success of lumbar fusion with internal fixation. Whether navigation robots can improve the efficacy and safety of screw placement is controversial. Thirty-eight patients who underwent oblique lateral lumbar interbody fusion internal fixation from March 2022 to May 2023 were retrospectively analyzed, 16 cases in the navigational robot group and 22 cases in the fluoroscopy group. Using visual analog score (VAS) for the low back and lower limbs, Oswestry Disability Index to compare the clinical efficacy of the 2 groups; using perioperative indexes such as the duration of surgery, intraoperative blood loss, intraoperative fluoroscopy times, and postoperative hospital stay to compare the safety of the 2 groups; and using accuracy of pedicle screws (APS) and the facet joint violation (FJV) to compare the accuracy of the 2 groups. Postoperative follow-up at least 6 months, there was no statistically significant difference between the 2 groups in the baseline data (P > .05). The navigational robot group's VAS-back was significantly lower than the fluoroscopy group at 3 days postoperatively (P < .05). However, the differences between the 2 groups in VAS-back at 3 and 6 months postoperatively, and in VAS-leg and Oswestry Disability Index at 3 days, 3 months, and 6 months postoperatively were not significant (P > .05). Although duration of surgery in the navigational robot group was significantly longer than in the fluoroscopy group (P > .05), the intraoperative blood loss and the intraoperative fluoroscopy times were significantly lower than in the fluoroscopy group (P < .05). The difference in the PHS between the 2 groups was not significant (P > .05). The APS in the navigation robot group was significantly higher than in the fluoroscopy group, and the rate of FJV was significantly lower than in the fluoroscopy group (P < .05). Compared with the traditional fluoroscopic technique, navigation robot-assisted lumbar interbody fusion with internal fixation provides less postoperative low back pain in the short term, with less trauma, less bleeding, and lower radiation exposure, as well as better APS and lower FJV, resulting in better clinical efficacy and safety.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11315524 | PMC |
http://dx.doi.org/10.1097/MD.0000000000039261 | DOI Listing |
Skeletal Radiol
December 2024
Brigham and Women's Hospital, 75 Francis Street, Boston, MA, 02215, USA.
Objective: To compare patient radiation exposure and procedure time for lumbar epidural steroid injections (ESIs) performed under CT-fluoroscopy (CTF) vs spiral CT-guidance.
Materials And Methods: A retrospective cohort study of 767 consecutive lumbar ESIs performed between 2015-2023 using CTF vs spiral CT-guidance was conducted. Patient characteristics (age, sex, weight), procedural characteristics (injection level, type of ESI, trainee participation), and outcomes (patient radiation exposure, procedure time, pain relief, complications) were compared.
Background: Jailed wire (JW) in the side branch (SB) is recommended during coronary bifurcation provisional stenting, but real benefit is unsure. Our objective was to evaluate benefit of a JW technique in the CABRIOLET registry.
Methods: In CABRIOLET, including 500 patients, we compared the primary composite endpoint poor final SB angiographic result (TIMI flow
J Cardiothorac Surg
December 2024
Department of Cardiothoracic Surgery, Suining Central Hospital, No. 127, Desheng Road, Chuanshan District, Suining, 629000, China.
Background: The conventional arteriovenous approach closure of patent ductus arteriosus (PDA) may be associated with more complications, especially in young infants. The objective is to explore the feasibility and clinical efficacy of interventional closure of PDA through a single venous approach under echocardiography without angiography.
Methods: 112 patients (32 males and 80 females) with PDA closed by different methods in Suining Central Hospital were enrolled, including 60 cases (Group 1) with a single venous approach under echocardiography without angiography and 52 cases (Group 2) with the conventional arteriovenous approach.
J Orthop Surg Res
December 2024
Department of Orthopedic Spine Surgery, Yan'an Hospital Affiliated to Kunming Medical University, 245, East of Renmin Road, 650051, Kunming, Yunnan, P.R. China.
Background: Degenerative lumbar spondylolisthesis (DLS) with lumbar spinal stenosis (LSS) is a common condition resulting in substantial lower back pain and disability. Surgical intervention is recommended only when conservative treatment fails. This study compared UBE-TLIF and MIS-TLIF regarding clinical outcomes and fusion rates in patients with single-segment DLS with LSS.
View Article and Find Full Text PDFJ Orthop Surg Res
December 2024
Department of Clinical Laboratory, Shengli Oilfield Central Hospital, No. 31 Jinan Road, Dongying, Shandong, 257034, China.
Background: To compare the efficacy of intramedullary nailing via the lateral parapatellar approach versus the infrapatellar approach in treating fractures at the tibial metaphyseal-diaphyseal junction.
Methods: A retrospective analysis was conducted on the clinical data of 45 patients with proximal or distal tibial fractures treated with intramedullary nailing via lateral parapatellar approach (n = 23) or infrapatellar approach (n = 22) between January 2019 and March 2023. We recorded and compared the operative time, intraoperative blood loss/fluoroscopies, success rate of closed reduction, anteroposterior and lateral entry point accuracy, postoperative infection, fracture healing time, as well as NRS pain scores, Lysholm knee function scores, and knee range of motion.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!