Background: Precise measurement of the intraosseous corridor within the superior pubic ramus is essential for the accurate percutaneous placement of a retrograde superior ramus screw (SRS). However, conventional manual measurement methods are often subjective, leading to variations in results among observers. Our goal was to develop an automated and dependable method for determining the retrograde SRS corridor.
Methods: We developed an automated technique that utilized a computed tomography (CT) image-based search algorithm to identify the retrograde SRS corridor with the maximum diameter. We evaluated the reliability of this automated approach in comparison to a manual method using 17 pelves. Subsequently, we used both methods to measure the diameter, length, and orientation of the retrograde SRS corridor in 204 pelves in a Chinese population and assessed the intra- and interobserver agreement of each method by calculating the root-mean-square error (RMSE) and constructing Bland-Altman plots. We determined the screw applicability (percentages of hemipelves that could be treated with specific sizes of screws) for each method. Additionally, we investigated potential factors influencing the corridor, such as sex, age, height, and weight, through regression analysis.
Results: The intra- and interobserver intraclass correlation coefficients (ICCs) for the automated method (0.998 and 0.995) were higher than those for the manual approach (0.925 and 0.918) in the assessment of the corridor diameter. Furthermore, the diameter identified by the automated method was notably larger than the diameter measured with the manual method, with a mean difference and RMSE of 0.9 mm and 1.1 mm, respectively. The automated method revealed a significantly smaller corridor diameter in females than in males (an average of 7.5 and 10.4 mm, respectively). Moreover, use of the automated method allowed 80.6% of the females to be managed with a 4.5-mm screw while a 6.5-mm screw could be utilized in 19.4%, surpassing the capabilities of the manual method. Female sex had the most substantial impact on corridor diameter (β = -0.583).
Conclusions: The automated method exhibited better reliability than the manual method in measuring the retrograde SRS corridor, and showed a larger corridor diameter for screw placement. Females had a significantly smaller corridor diameter than males. Given the intricate nature of the automated approach, which entails utilizing different software and interactive procedures, our current method is not readily applicable for traumatologists. We are working on developing integrated software with the goal of providing a more user-friendly solution for traumatologists in the near future.
Level Of Evidence: Diagnostic Level III . See Instructions for Authors for a complete description of levels of evidence.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.2106/JBJS.23.00695 | DOI Listing |
Best Pract Res Clin Anaesthesiol
March 2024
1400 Holcombe Blvd, FC 13.2000, Houston, TX, 77030, USA. Electronic address:
Lung cancer is among one of the most commonly diagnosed malignancies and is the leading cause of cancer-related mortality in both men and women globally, with an estimated 1.8 million deaths annually. Moreover, it is also the leading cause of cancer related deaths in the United States (U.
View Article and Find Full Text PDFCancer Med
January 2025
Department of Orthopaedics and Traumatology, School of Clinical Medicine, Faculty of Medicine, The University of Hong Kong, Hong Kong, Hong Kong.
Background: By simultaneously staining multiple immunomarkers on a single tissue section, multiplexed immunohistochemistry (mIHC) enhances the amount of information that can be observed in a single tissue section and thus can be a powerful tool to visualise cellular interactions directly in the tumour microenvironment. Performing mIHC remains technically and practically challenging, and this technique has many limitations if not properly validated. However, with proper validation, heterogeneity between histopathological images can be avoided.
View Article and Find Full Text PDFPhysiother Res Int
January 2025
Department of Biomedical Engineering, University of Engineering and Technology (UET) Lahore, Narowal Campus, Narowal, Pakistan.
Background And Purpose: Throwing a baseball involves intense exposure of the arm to high speeds and powerful forces, which contributes to an increasing prevalence of arm injuries among athletes. Traditional rigid exoskeletons and rehabilitation equipment frequently lack portability, safety, ergonomic design, and affordability. Traditional rehabilitation approaches frequently require therapist monitoring, resulting in therapy delays.
View Article and Find Full Text PDFEur Heart J Cardiovasc Imaging
January 2025
Sorbonne Université, unité d'imagerie cardiovasculaire et thoracique, Hôpital La Pitié Salpêtrière (AP-HP), Laboratoire d'Imagerie Biomédicale, INSERM, CNRS, Institute of Cardiometabolism and Nutrition, ACTION Group, Paris, France.
Purpose: Epicardial adipose tissue (EAT) could contribute to the specific atherosclerosis profile observed in premature coronary artery disease (pCAD) characterized by accelerated plaque burden (calcified and non-calcified), high risk plaque features (HRP) and ischemic recurrence. Our aims were to describe EAT volume and density in pCAD compared to asymptomatic individuals matched on CV risk factors and to study their relationship with coronary plaque severity extension and vulnerability.
Materials And Methods: 208 patients who underwent coronary computed tomography angiography (CCTA) were analyzed.
Int J Med Robot
February 2025
Department of Urology, The Affiliated Hospital of Qingdao University, Qingdao, China.
Background: The emergence of telesurgery has received global interest, with secure network transmission identified as a crucial determinant of its success. This study aimed to evaluate the safety and viability of employing quantum cryptography communication in remote partial nephrectomy.
Methods: The surgeon operated on the patient from a distance of over 260 km using remote control of a surgical robot.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!