Background: Not all surgical osteotomy steps have been properly investigated for their potential impact on surgical accuracy. The main study objective was to investigate the osteotomy parameters that have respectively major and minor impact on coronal and sagittal bony accuracy in medial opening-wedge high tibial osteotomy (MOWHTO).
Methods: Three tibias from an existing 3D MOWHTO osteotomy database were chronologically selected based on segmentation quality, tibial plateau size and the presence of tibial varus. The study consisted of three parts: (I) translating the hinge axis in the coronal plane and switching the osteotomy starting point (30-40 mm) and depth, (II) the hinge axis was rotated stepwise by 10° to perform five simulations, (III) the hinge axis was rotated in the axial plane stepwise by 10° towards anterolateral to perform four simulations (0°, +10°, +20°, +30°). The medial proximal tibial angle (MPTA) and lateral tibial slope were the primary outcomes. Simulations were performed with 5, 10 and 15 mm gap distraction.
Results: In the coronal plane, maximum difference in osteotomy depth was 10 mm which represented an MPTA difference of 0.8°-1.1° in 10 mm gap distraction and 1.2°-2.0° in 15 mm gap distraction. Tibial slope remained unchanged. Rotating the hinge axis in the sagittal plane delivered minor changes on both MPTA (<0.5°) and tibial slope (<1.5°) at 10 mm gap distraction. Per 10° of axial rotation of the hinge axis towards anterolateral, the tibial slope increased by 1.0°-1.3° in 10 mm gap distraction while the MPTA remains nearly unchanged.
Conclusions: The study showed that the medio-lateral osteotomy length is the main parameter for obtaining bony accuracy in the coronal plane and maintaining a strict perpendicular axial hinge axis position is crucial in preserving the native tibial slope. Correct axial alignment of the hinge axis can be obtained by creating an equal osteotomy depth of the anterior and posterior tibial cortices in the lateral metaphyseal area.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11304427 | PMC |
http://dx.doi.org/10.21037/atm-23-1870 | DOI Listing |
J Cardiovasc Magn Reson
December 2024
IRCCS Humanitas Research Hospital, Via Alessandro Manzoni, 56, 20089 Rozzano, Milano, Italy; Department of Biomedical Sciences, Humanitas University, Via Rita Levi Montalcini, 4, 20090 Pieve Emanuele, Milano, Italy. Electronic address:
Cureus
December 2024
Department of Orthopaedics and Traumatology, All India Institute of Medical Sciences, Raipur, Raipur, IND.
Anat Rec (Hoboken)
December 2024
Biology Department, Northland Pioneer College, Holbrook, Arizona, USA.
Nothronychus graffami was a large therizinosaur represented by a single well-preserved individual from the Turonian Tropic Shale of southern Utah. It is characterized by an enlarged abdomen, small tail, and an extensively pneumatized axial skeleton, and is frequently regarded as herbivorous. Given the overall tail reduction and the development of a wide fused synsacrum with widely spaced acetabulae, it is reconstructed with an anteriorly rotated femur and a displaced resting ground reaction force anterior to the center of mass.
View Article and Find Full Text PDFAm J Sports Med
December 2024
Department of Orthopaedics, Balgrist University Hospital, University of Zurich, Zurich, Switzerland.
Background: If an increased posterior tibial slope (PTS) and concomitant unicompartmental osteoarthritis are present, a simultaneous sagittal (slope) and coronal correcting high tibial osteotomy has been recommended. However, no study has investigated the accuracy of such combined high tibial slope correction osteotomies.
Purpose: (1) To report the accuracy of navigated high tibial slope correction osteotomies using patient-specific instruments (PSI) and (2) to analyze the influence of an open wedge osteotomy (OWO) versus a closed wedge osteotomy (CWO) and the hinge axis angle (HAA) on the accuracy of the PTS correction.
Advances in the generation of structured light beams have led to their increased adoption in various applications such as laser-based material processing, optical microscopy, and optical communication. However, the reliability of these beams, particularly Laguerre-Gauss beams, further hinges on their resilience against damage caused by obstructions. In this work, the self-reconstruction of Laguerre-Gauss beams upon on-axis obstruction is analyzed by modeling the obstructed beam in terms of two orthogonal components-one component representing the attenuated beam and another representing the perturbation by the obstruction.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!