Purpose: To determine if an improvement in cord-level intraoperative neuromonitoring (IONM) data following data loss results in a reduced risk for new postoperative motor deficit in pediatric and adult spinal deformity surgery.

Methods: A consecutive series of 1106 patients underwent spine surgery from 2015 to 2023 by a single surgeon. Cord alerts were defined by Somatosensory-Evoked Potentials (SSEP; warning criteria: 10% increase in latency or > 50% loss in amplitude) and Motor-Evoked Potentials (MEP; warning criteria: 75% loss in amplitude without return to acceptable limits after stimulation up 100 V above baseline level). Timing of IONM loss and recovery, interventions, and baseline/postoperative day 1 (POD1) lower extremity motor scores were analyzed.

Results: IONM Cord loss was noted in 4.8% (53/11,06) of patients and 34% (18/53) with cord alerts had a POD1 deficit compared to preoperative motor exam. MEP and SSEP loss attributed to 98.1% (52/53) and 39.6% (21/53) of cord alerts, respectively. Abnormal descending neurogenic-evoked potential (DNEP) was seen in 85.7% (12/14) and detected 91.7% (11/12) with POD1 deficit. Abnormal wake-up test (WUT) was seen in 38.5% (5/13) and detected 100% (5/5) with POD1 deficit. Most cord alerts occurred during a three-column osteotomy (N = 23/53, 43%); decompression (N = 12), compression (N = 7), exposure (N = 4), and rod placement (N = 14). Interventions were performed in all 53 patients with cord loss and included removing rods/less correction (N = 11), increasing mean arterial pressure alone (N = 10), and further decompression with three-column osteotomy (N = 9). After intervention, IONM data improved in 45(84.9%) patients (Full improvement: N = 28; Partial improvement: 17). For those with full and partial IONM improvement, the POD1 deficit was 10.7% (3/28) and 41.2% (7/17), respectively. For those without any IONM improvement (15.1%, 8/53), 100% (8/8) had a POD1 deficit, P < 0.001.

Conclusion: A full or partial improvement in IONM data loss after intraoperative intervention was significantly associated with a lower risk for POD1 deficit with an absolute risk reduction of 89.3% and 58.8%, respectively. All patients without IONM improvement had a POD1 neurologic deficit.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s43390-024-00944-6DOI Listing

Publication Analysis

Top Keywords

pod1 deficit
20
cord alerts
16
improvement cord-level
8
cord-level intraoperative
8
intraoperative neuromonitoring
8
reduced risk
8
risk postoperative
8
ionm data
8
warning criteria
8
loss amplitude
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!