Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: To culturally adapt the Musculoskeletal Health Questionnaire (MSK-HQ) to European Portuguese and evaluate its reliability in individuals with musculoskeletal conditions.
Materials And Methods: The study was carried out in two phases. In the first phase, the MSK-HQ was translated and culturally adapted. In the second phase, a longitudinal observational study was carried out with a convenience sample of participants with musculoskeletal conditions. Data collection began at the start of physiotherapy treatments by filling in the MSK-HQ and Numeric Pain Rating Scale (NPRS). After 4-7 days, the participants were asked to fill out the MSK-HQ once again, as well as the Patient Global Improvement Change (PGIC) scale. The data collected was used to study internal consistency, test-retest reliability, and measurement error. Floor and ceiling effects were also analysed.
Results: The MSK-HQ was successfully translated and adapted into European Portuguese. The second phase of the study had a sample of 191 participants. This study demonstrated high internal consistency (Cronbach's α = 0.885) and excellent test-retest reliability (ICC(2,1) = 0.908). The analysis of measurement error resulted in an SEM of 2.818 and an SDC at 7.811. No floor or ceiling effect was observed.
Conclusions: The MSK-HQ-PT is a reliable instrument for measuring musculoskeletal health. Further studies on its validity and responsiveness are needed.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11309473 | PMC |
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0308623 | PLOS |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!