A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

An All-in-One Array of Pressure Sensors and sEMG Electrodes for Scoliosis Monitoring. | LitMetric

An All-in-One Array of Pressure Sensors and sEMG Electrodes for Scoliosis Monitoring.

Small

Key Laboratory of Advanced Technologies of Materials (Ministry of Education), School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu, Sichuan, 610031, P. R. China.

Published: November 2024

Scoliosis often occurs in adolescents and seriously affects physical development and health. Traditionally, medical imaging is the most common means of evaluating the corrective effect of bracing during treatment. However, the imaging approach falls short in providing real-time feedback, and the optimal corrective force remains unclear, potentially slowing the patient's recovery progress. To tackle these challenges, an all-in-one integrated array of pressure sensors and sEMG electrodes based on hierarchical MXene/chitosan/polydimethylsiloxane (PDMS)/polyurethane sponge and MXene/polyimide (PI) is developed. Benefiting from the microstructured electrodes and the modulus enhancement of PDMS, the sensor demonstrates a high sensitivity of 444.3 kPa and a broad linear detection range (up to 81.6 kPa). With the help of electrostatic attraction of chitosan and interface locking of PDMS, the pressure sensor achieves remarkable stability of over 100 000 cycles. Simultaneously, the sEMG electrodes offer exceptional stretchability and flexibility, functioning effectively at 60% strain, which ensures precise signal capture for various human motions. After integrating the developed all-in-one arrays into a commercial scoliosis brace, the system can accurately categorize human motion and predict Cobb angles aided by deep learning. This study provides real-time insights into brace effectiveness and patient progress, offering new ideas for improving the efficiency of scoliosis treatment.

Download full-text PDF

Source
http://dx.doi.org/10.1002/smll.202404136DOI Listing

Publication Analysis

Top Keywords

semg electrodes
12
array pressure
8
pressure sensors
8
sensors semg
8
all-in-one array
4
electrodes
4
scoliosis
4
electrodes scoliosis
4
scoliosis monitoring
4
monitoring scoliosis
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!