A bronchoscopic navigation method based on neural radiation fields.

Int J Comput Assist Radiol Surg

State Key Laboratory of Digital Medical Engineering, Jiangsu Key Lab of Robot Sensing and Control, School of Instrument Science and Engineering, Southeast University, Nanjing, China.

Published: October 2024

Purpose: We introduce a novel approach for bronchoscopic navigation that leverages neural radiance fields (NeRF) to passively locate the endoscope solely from bronchoscopic images. This approach aims to overcome the limitations and challenges of current bronchoscopic navigation tools that rely on external infrastructures or require active adjustment of the bronchoscope.

Methods: To address the challenges, we leverage NeRF for bronchoscopic navigation, enabling passive endoscope localization from bronchoscopic images. We develop a two-stage pipeline: offline training using preoperative data and online passive pose estimation during surgery. To enhance performance, we employ Anderson acceleration and incorporate semantic appearance transfer to deal with the sim-to-real gap between training and inference stages.

Results: We assessed the viability of our approach by conducting tests on virtual bronchscopic images and a physical phantom against the SLAM-based methods. The average rotation error in our virtual dataset is about 3.18 and the translation error is around 4.95 mm. On the physical phantom test, the average rotation and translation error are approximately 5.14 and 13.12 mm.

Conclusion: Our NeRF-based bronchoscopic navigation method eliminates reliance on external infrastructures and active adjustments, offering promising advancements in bronchoscopic navigation. Experimental validation on simulation and real-world phantom models demonstrates its efficacy in addressing challenges like low texture and challenging lighting conditions.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s11548-024-03243-7DOI Listing

Publication Analysis

Top Keywords

bronchoscopic navigation
24
bronchoscopic
8
navigation method
8
bronchoscopic images
8
external infrastructures
8
physical phantom
8
average rotation
8
translation error
8
navigation
5
method based
4

Similar Publications

Background Airway foreign body aspiration is an emergency predominantly observed in children and the elderly. However, it also occurs in adults, presenting with a variety of symptoms. Both rigid and flexible bronchoscopies are employed for foreign body retrieval.

View Article and Find Full Text PDF

Background: This study aimed to quantify radiation doses during navigational bronchoscopy procedures, comparing them with reported cohorts and evaluating the LungVision (Body Vision Medical Inc.) system's efficacy in dose reduction.

Methods: This retrospective observational study included 52 consecutive navigational bronchoscopy cases, categorized into 4 imaging groups based on the C-arm: Cios Spin (Siemens Healthineers), or OEC 9900 (GE HealthCare); and the 3D tomographic imaging algorithm: Cios Spin's onboard imaging, or LungVision's AI-driven imaging.

View Article and Find Full Text PDF

Robotic bronchoscopy: Evolution of advanced diagnostic technologies for pulmonary lesions.

Best Pract Res Clin Anaesthesiol

March 2024

1400 Holcombe Blvd, FC 13.2000, Houston, TX, 77030, USA. Electronic address:

Lung cancer is among one of the most commonly diagnosed malignancies and is the leading cause of cancer-related mortality in both men and women globally, with an estimated 1.8 million deaths annually. Moreover, it is also the leading cause of cancer related deaths in the United States (U.

View Article and Find Full Text PDF

Intraoperative Transbronchial Metallic Coil Marking for Small Peripheral Pulmonary Lesions in a Hybrid Operation Room.

Cancers (Basel)

December 2024

Department of Thoracic and Endocrine Surgery and Oncology, Institute of Biomedical Sciences, Tokushima University Graduate School, Kuramoto-cho, Tokushima 770-8503, Japan.

: Computed tomography (CT)-guided transbronchial metallic coil marking is useful for identifying the locations of small peripheral pulmonary lesions. Even deeply located lesions may be accurately identified and resected with adequate margins. This method is also applicable to multiple lesions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!