A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Photoacoustic imaging of a cyanine dye targeting bacterial infection. | LitMetric

The development of a non-invasive infection-specific diagnostic probe holds the potential to vastly improve early-stage detection of infection, enabling precise therapeutic intervention and potentially reducing the incidence of antibiotic resistance. Towards this goal, a commercially available bacteria-targeting Zinc(II)-dipicolylamine (ZnDPA)-derived fluorophore, PSVue794, was assessed as a photoacoustic (PA) imaging probe (PIP). A radiolabeled version of the dye, [Tc]Tc-PSVue794, was developed to facilitate quantitative biodistribution studies beyond optical imaging methods, which showed a target-to-non-target ratio of 10.1 ± 1.1, 12 h post-injection. The ability of the PIP to differentiate between bacterial infection, sterile inflammation, and healthy tissue in a mouse model, was then evaluated via PA imaging. The PA signal in sites of sterile inflammation (0.062 ± 0.012 a.u.) was not statistically different from that of the background (0.058 ± 0.006 a.u.). In contrast, high PA signal was detected at sites of bacterial infection (0.176 ± 0.011 a.u.) as compared to background (0.081 ± 0.04 a.u., where P ≤ 0.03). This work demonstrates the potential of utilizing established fluorophores towards PAI and utilizing PAI as a modality in the distinction of bacterial infection from sites of sterile inflammation.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11306741PMC
http://dx.doi.org/10.1038/s41598-024-69148-2DOI Listing

Publication Analysis

Top Keywords

bacterial infection
16
sterile inflammation
12
photoacoustic imaging
8
sites sterile
8
infection
5
imaging cyanine
4
cyanine dye
4
dye targeting
4
bacterial
4
targeting bacterial
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!