Objective: For many health care providers, an umbilical venous catheter (UVC) may be a contraindication for skin-to-skin contact (SSC). Our aim was to compare the frequency of adverse events between preterm infants who were on SSC with UVC and those who remained in an incubator.
Study Design: Prospective observational study in newborns less than 35 weeks gestation. UVC-related adverse events were compared between neonates who performed SSC and those who did not. The incidence of catheter-related displacement, leak, loss, hemorrhage, malfunction, and bloodstream infection was studied.
Results: From 226 patients, 171 performed SSC with UVC. Their first contact was earlier than in those who remained in an incubator (SSC-UVC, 29 hours [interquartile range (IQR): 21-53] vs. no SSC-UVC, 132 hours [IQR: 96-188]; < 0.001). Both groups were similar in gestational age (SSC-UVC, 30 weeks vs. no SSC-UVC, 30.3 weeks; = 0.331) and birth weight (SSC-UVC, 1,285 g vs. no SSC-UVC, 1,355 g; = 0.2). Studied complications were not more frequent in patients who performed SSC. In fact, although it was not statistically significant, a lower overall incidence of adverse events (SSC-UVC, 13.5% vs. no SSC-UVC, 20%; = 0.237) and catheter-related bloodstream infection (SSC-UVC, 4.7% vs. no SSC-UVC, 10.9%; = 0.111) was observed in this group.
Conclusion: SSC with a UVC is a safe procedure and there are no more complications in newborns who perform SSC compared to those who remain in the incubator. Due to its demonstrated benefits, SSC should be promoted in premature newborns regardless of the presence of a UVC.
Key Points: · SSC in preterm infants with UVCs is safe.. · Early SSC does not increase UVC-related bloodstream infection.. · Early SSC should be promoted in stable patients regardless of the presence of a UVC..