Purpose: The diagnosis of retained intraorbital organic foreign body can pose significant challenges without corroboration from a detailed patient history even when presented with clear and accurate imaging.

Observations: We present a case of a 65-year-old woman with an upper lid lesion that she noticed 1.5 years ago which subsequently became inflamed four weeks before evaluation. A one cm-long green plant stem was removed from a superior orbital tract, leading to symptom resolution. The patient recalled a fall three years prior, during which the initial embedding occurred. Following the fall, she experienced binocular diplopia for two months which spontaneously resolved.

Conclusions And Importance: We believe this is one of the first cases of a retained intraorbital organic foreign body that initially presented with symptoms, resolved, and subsequently presented years later with different symptoms, leading to the discovery of the foreign body. This case serves as an important reminder to physicians that retained organic foreign bodies can have long quiescent periods and delayed clinical presentations.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11301227PMC
http://dx.doi.org/10.1016/j.ajoc.2024.102093DOI Listing

Publication Analysis

Top Keywords

organic foreign
12
foreign body
12
retained intraorbital
8
intraorbital organic
8
three year
4
retained
4
year retained
4
retained orbital
4
orbital plant
4
plant material
4

Similar Publications

Object: This study aims to analyze the clinical characteristics of children with tracheobronchial foreign body and to investigate the factors influencing the surgical duration of rigid bronchoscopic foreign body removal under general anesthesia.

Methods: We retrospectively identified 421 children diagnosed with tracheobronchial foreign body undergoing rigid bronchoscopy between January 2020 and December 2021. A comprehensive analysis was conducted on patient demographics, including age, weight, gender, American Society of Anesthesiologists (ASA) physical status classification, foreign body type and location, duration of foreign body retention, preoperative symptoms, signs, imaging findings, tracheobronchial manifestations observed during bronchoscopy, and surgical durations.

View Article and Find Full Text PDF

Background Airway foreign body aspiration is an emergency predominantly observed in children and the elderly. However, it also occurs in adults, presenting with a variety of symptoms. Both rigid and flexible bronchoscopies are employed for foreign body retrieval.

View Article and Find Full Text PDF

Aspirated foreign bodies in children: 10-Years experience in a single tertiary centre in New Zealand.

Int J Pediatr Otorhinolaryngol

January 2025

Department of Paediatric Otorhinolaryngology, Starship Children's Hospital, 2 Park Road, Grafton, Auckland, 1023, New Zealand.

Objective: Aspirated foreign bodies (FB) are potentially life-threatening conditions which can be challenging to diagnose in children. The previous similar study from our hospital, published in 2014, created a guideline suggesting when to proceed to laryngobronchoscopy (LB) in suspected FB aspiration with over 99 % sensitivity. The grading system included the presence or absence of acute history, positive examination, and/or radiological findings, including witnessed choking, dysphonia, stridor, wheezing, or reduced air entry on examination or abnormal radiological findings.

View Article and Find Full Text PDF

Stretchable Thermochromic Fluorescent Fibers Based on Self-Crystallinity Phase Change for Smart Wearable Displays.

Polymers (Basel)

December 2024

Engineering Research Center of Technical Textiles, Ministry of Education, College of Textiles, Donghua University, Shanghai 201620, China.

Smart fibers with tunable luminescence properties, as a new form of visual output, present the potential to revolutionize personal living habits in the future and are receiving more and more attention. However, a huge challenge of smart fibers as wearable materials is their stretching capability for seamless integration with the human body. Herein, stretchable thermochromic fluorescent fibers are prepared based on self-crystallinity phase change, using elastic polyurethane (PU) as the fiber matrix, to meet the dynamic requirements of the human body.

View Article and Find Full Text PDF

Current status and strategies for controlling hexachlorobutadiene from multiple perspectives of emission, occurrence, and disposal.

Environ Res

January 2025

Key Laboratory of Environmental Nanotechnology and Health Effects, State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, P.O. Box 2871, Beijing, 100085, China; University of Chinese Academy of Sciences, Beijing, 100049, China. Electronic address:

Hexachlorobutadiene (HCBD), as an emerging persistent organic pollutant, poses a pressing global environmental issue concerning its reduction and control. However, the lack of systematic studies on the sources and occurrence of HCBD hinders the development of effective disposal technologies. This study addresses HCBD prevention and treatment from multiple perspectives, including source emissions, environmental contamination distribution, and control technologies.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!