Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Study Design: Review of database.
Setting: Tertiary care neurotology center.
Patients: Patients undergoing adverse events.
Intervention: MAUDE database evaluation of Eustachian tube balloon dilation (ETBD) for the treatment of Eustachian tube dysfunction.
Main Outcome Measures: Medical device reports (MDRs) from the MAUDE database were analyzed for adverse patient events (AE) and device malfunctions (DM) among different devices for ETBD. The objective of this analysis is to assess AE rates and compare them across different devices. Sales data was also used to calculate AE rates.
Results: There were 18 MDRs noted in the MAUDE database for patients undergoing ETBD out of an initial 23 results. When separated into devices, the Aera had 9 total MDRs (50 %), Xpress had 8 (44.4 %) and Audion had 1 (5.6 %). There were 10 AE and 8 DM. When separated by device, Aera had 4 AEs and 5 DMs, Xpress had 5 AEs and 3 DMs, and Audion had 1 AE. The most common AE was subcutaneous emphysema (n = 4), in the head and neck region with one report of mediastinal involvement. Using this sales data, the Aera balloon has an MDR rate of 0.0128 % is established, with a rate of AE at 0.0058 %. The Audion balloon had an MDR and AE rate of 0.0164 %.
Conclusions: ETBD is a safe procedure with minimal complications, with subcutaneous emphysema being the most commonly reported adverse event, consistent with literature findings. A comprehensive analysis of AE, coupled with sales data, indicates a commendably low MDR rate of 0.0128 % for the Aera balloon while the Audion balloon had an MDR rate of 0.0164 %. These findings offer valuable insights on post-procedure expectations and engaging in informed consent discussions with patients, highlighting the overall safety of ETBD as an intervention.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.amjoto.2024.104481 | DOI Listing |