A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

MAUDE database and Eustachian tube balloon dilation: Evaluation of adverse events and sales data. | LitMetric

Study Design: Review of database.

Setting: Tertiary care neurotology center.

Patients: Patients undergoing adverse events.

Intervention: MAUDE database evaluation of Eustachian tube balloon dilation (ETBD) for the treatment of Eustachian tube dysfunction.

Main Outcome Measures: Medical device reports (MDRs) from the MAUDE database were analyzed for adverse patient events (AE) and device malfunctions (DM) among different devices for ETBD. The objective of this analysis is to assess AE rates and compare them across different devices. Sales data was also used to calculate AE rates.

Results: There were 18 MDRs noted in the MAUDE database for patients undergoing ETBD out of an initial 23 results. When separated into devices, the Aera had 9 total MDRs (50 %), Xpress had 8 (44.4 %) and Audion had 1 (5.6 %). There were 10 AE and 8 DM. When separated by device, Aera had 4 AEs and 5 DMs, Xpress had 5 AEs and 3 DMs, and Audion had 1 AE. The most common AE was subcutaneous emphysema (n = 4), in the head and neck region with one report of mediastinal involvement. Using this sales data, the Aera balloon has an MDR rate of 0.0128 % is established, with a rate of AE at 0.0058 %. The Audion balloon had an MDR and AE rate of 0.0164 %.

Conclusions: ETBD is a safe procedure with minimal complications, with subcutaneous emphysema being the most commonly reported adverse event, consistent with literature findings. A comprehensive analysis of AE, coupled with sales data, indicates a commendably low MDR rate of 0.0128 % for the Aera balloon while the Audion balloon had an MDR rate of 0.0164 %. These findings offer valuable insights on post-procedure expectations and engaging in informed consent discussions with patients, highlighting the overall safety of ETBD as an intervention.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.amjoto.2024.104481DOI Listing

Publication Analysis

Top Keywords

maude database
16
sales data
16
mdr rate
16
eustachian tube
12
balloon mdr
12
tube balloon
8
balloon dilation
8
patients undergoing
8
mdrs maude
8
aes dms
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!