Area normalization of HERFD-XANES spectra.

J Synchrotron Radiat

ESRF - The European Synchrotron, 71 Avenue des Martyers, 38000 Grenoble, France.

Published: September 2024

AI Article Synopsis

Article Abstract

The normalization of X-ray absorption near-edge structure (XANES) spectra is required for comparing spectral features and extracting quantitative information in analytical techniques such as linear combination analysis, principal component analysis and multivariate curve resolution. Most published data are normalized to the edge-jump, but normalization to the spectral area has also been applied. The latter is particularly attractive if only a small energy range around the absorption can be recorded reliably. Here, the two normalization methods are compared at the L-edge of Pt, Pd and Rh, and at the Ni K-edge using experimental and calculated spectra. Normalization to the spectral area is found to be a viable approach if the range for the area normalization is sufficiently large.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11371039PMC
http://dx.doi.org/10.1107/S1600577524005307DOI Listing