There is an ongoing need to do more with less and provide highly multiplexed analysis from limited sample volumes. Improved "sample sparing" assays would have a broad impact across pediatric and other rare sample type studies in addition to enabling sequential sampling. This capability would advance both clinical and basic research applications. Here we report the micro blood analysis technology (μBAT), a microfluidic platform that supports multiplexed analysis of neutrophils from a single drop of blood. We demonstrate the multiplexed orthogonal capabilities of μBAT including functional assays (phagocytosis, neutrophil extracellular traps, optical metabolic imaging) and molecular assays (gene expression, cytokine secretion). Importantly we validate our microscale platform using a macroscale benchmark assay. μBAT is compatible with lancet puncture or microdraw devices, and its design facilitates rapid operations without the need for specialized equipment. μBAT offers a new method for investigating neutrophil function in populations with restricted sample amounts.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11335436PMC
http://dx.doi.org/10.1039/d4lc00333kDOI Listing

Publication Analysis

Top Keywords

multiplexed analysis
12
micro blood
8
blood analysis
8
analysis technology
8
technology μbat
8
analysis
5
μbat
5
multiplexed
4
μbat multiplexed
4
analysis neutrophil
4

Similar Publications

Spatially selective imaging (SSI) involves sampling a group of pixels from different positions on an encoded object to display a decoded image. Here, SSI is achieved by using off-axis cylindrical Fresnel lens arrays to decode multiple images from an encoded print of structural color pixels. Each image is optically retrieved by separately placing different "keys" (arrays of lenses in different pseudorandom configurations) over the same encoded print, and then each image is digitally reconstructed for visualization.

View Article and Find Full Text PDF

Background: Recent studies have highlighted the distinct ratio of PD-1 + Treg/PD-1 + CD8 for prognosis prediction. However, it remains unclear about the association of this ratio and tertiary lymphoid structures (TLS) with prognosis and response to neoadjuvant or conversion therapy in advanced gastric cancer.

Methods: Firstly, fresh postoperative samples from 68 gastric cancer patients in Renji Hospital were collected.

View Article and Find Full Text PDF

Characterization of serological responses to Plasmodium falciparum (Pf) is of interest to understand disease burden and transmission dynamics; however, their interpretation is challenging. Dried blood spots from 30,815 participants aged 6 months to 15 years from the 2018 Nigeria HIV/AIDS Indicator and Impact Survey were analyzed by multiplex bead-based assay to measure immunoglobulin G (IgG) to Pf-stage-specific MSP-1, AMA-1, GLURPR0, LSA-1, and CSP. These IgG levels were analyzed by principal component analysis (PCA).

View Article and Find Full Text PDF

Background: Serology for dengue viruses (DENV) and Zika virus (ZIKV) has been hindered by antibody cross-reactivity, which limits the utility of these tests for surveillance and assessment of sero-status. Our aim was to develop a multiplexed IgG-based assay with increased accuracy to assess the history of previous DENV and ZIKV infections.

Methods: We developed and assessed the analytical performance of a sample-sparing, multiplexed, microsphere-based serological assay using domain III of the envelope protein (EDIII) of DENV serotypes 1-4 and ZIKV, the most variable region between each virus.

View Article and Find Full Text PDF

N-Acetyltyrosine as a Biomarker of Parenteral Nutrition Administration in First-Tier Newborn Screening Assays.

Int J Neonatal Screen

December 2024

Division of Laboratory Sciences, National Center for Environmental Health, Centers for Disease Control and Prevention, 4770 Buford Hwy NE, S110-3, Atlanta, GA 30341, USA.

Parenteral nutrition (PN) is a nutrient solution administered intravenously (IV) to premature babies. PN causes elevations of some amino acids in blood samples that are also biomarkers used in newborn screening (NBS). Therefore, PN status must be annotated by clinicians on dried blood spot (DBS) cards to reduce NBS laboratory burdens associated with potential false results; however, NBS laboratories continue to receive DBSs with misannotated PN status.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!