A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Microinterventional system for robot-assisted gonioscopic surgery- technical feasibility and preclinical evaluation in synthetic eye models. | LitMetric

Background: Preclinical technical feasibility study of robot-assisted microinvasive glaucoma surgery using a novel ophthalmic robot-assisted surgery system.

Methods: Feasibility was assessed in synthetic eye models in two stages: Stage I, nonimplantable robot-assisted goniotomy; and Stage II, robot-assisted stent implantation using a trabecular bypass stent. Robot-assisted interventions were subsequently compared to the manual approach.

Results: Stage I: Two surgeons completed 10 trials each of ab-interno sectoral goniotomy with and without robotic assistance for at least 3 clock hours using a standard goniotomy knife and more than 10 clock hours of extended goniotomy using a flexible, guided goniotomy instrument. Stage II: Trabecular bypass stent deployment was successfully achieved in 100% of the attempts with and without robotic assistance. Surgical time was recorded and compared between the robotic-assisted and the manual approach.

Conclusions: A system for robot-assisted microinvasive glaucoma surgery can successfully achieve implantable and nonimplantable interventions in the anterior segment. This is the first known demonstration of the feasibility of robot-assisted glaucoma surgery.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11299419PMC
http://dx.doi.org/10.1186/s12886-024-03595-3DOI Listing

Publication Analysis

Top Keywords

glaucoma surgery
12
robot-assisted
8
system robot-assisted
8
technical feasibility
8
synthetic eye
8
eye models
8
robot-assisted microinvasive
8
microinvasive glaucoma
8
trabecular bypass
8
bypass stent
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!