AI Article Synopsis

  • The study investigated the relationship between serum biomarker levels and hand-arm vibration injury in 92 patients, focusing on the severity of Raynaud's phenomenon (RP) and neurosensory issues.
  • It utilized statistical methods, including Jonckheere's trend test and generalized linear models, to analyze associations with biomarker levels, exposure magnitude, and duration.
  • Key findings indicated that certain biomarkers, such as thrombomodulin and CGRP, were positively associated with the severity of RP and neurosensory symptoms, while no correlations with exposure levels were found for some biomarkers.

Article Abstract

Our aim was to explore possible relationships between serum levels of biomarkers in patients with hand-arm vibration injury in relation to the severity of the vascular, i.e., Raynaud's phenomenon (RP), and neurosensory manifestations, the current exposure level, and the duration of exposure. This study was of case series design and involved 92 patients diagnosed with hand-arm vibration injury. Jonckheere's trend test was used to assess any association between serum levels of biomarkers and RP as well as neurosensory manifestations, graded by the International Consensus Criteria. Generalized linear models with adjustment for possible confounders were also used for associations between serum levels of biomarkers and; (1) severity of RP recorded as the extent of finger blanching calculated with Griffin score, (2) vibration perception thresholds, (3) magnitude of current exposure as [A(8); (m/s)] value, and (4) the duration of exposure in years. Serum levels of thrombomodulin, von Willebrand factor, calcitonin gene related peptide (CGRP), heat shock protein 27, and caspase-3 were positively associated with severity of RP. Serum levels of CGRP were positively associated with the neurosensory component. No associations with exposure were shown for these biomarkers. For Intercellular adhesion molecule 1 and monocyte chemoattractant protein 1, no associations were found with neither severity nor exposure. Levels of serum biomarkers associated with endothelial injury or dysfunction, inflammation, vasodilation, neuroprotection, and apoptosis were positively associated with the severity of hand-arm vibration injury.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11300662PMC
http://dx.doi.org/10.1038/s41598-024-68846-1DOI Listing

Publication Analysis

Top Keywords

serum levels
24
levels biomarkers
16
hand-arm vibration
16
vibration injury
16
neurosensory manifestations
12
positively associated
12
biomarkers severity
8
raynaud's phenomenon
8
phenomenon neurosensory
8
patients hand-arm
8

Similar Publications

Simulated microgravity predisposes kidney to injury through promoting intrarenal artery remodeling.

FASEB J

January 2025

Department of Nephrology, State Key Laboratory of Kidney Diseases, Beijing Key Laboratory of Kidney Disease Research, National Clinical Research Center for Kidney Diseases, Nephrology Institute of the Chinese People's Liberation Army, Chinese PLA General Hospital, Beijing, China.

Spaceflight-induced multi-organ dysfunction affects the health of astronauts and the safety of in-orbit flight. However, the effect of microgravity on the kidney and the underlying mechanisms are unknown. In the current study, we used a hindlimb unweighting (HU) animal model to simulate microgravity and employed histological analysis, ischemia-reperfusion experiments, renal ultrasonography, bioinformatics analysis, isometric force measurement, and other molecular experimental settings to evaluate the effects of microgravity on the kidneys and the underlying mechanisms involved in this transition.

View Article and Find Full Text PDF

Kidney function estimation equations: a narrative review.

Ir J Med Sci

January 2025

Department of Nephrology, Kasturba Medical College, Manipal, Manipal Academy of Higher Education, Manipal, Karnataka, India.

Glomerular filtration rate (GFR) as a marker of kidney function is important in health and disease management because decreased kidney function is associated with all-cause and cardiovascular mortality, progression of kidney disease, predisposition to acute kidney injury (AKI), and for drug dosage modification. While measured glomerular filtration rate (mGFR) is acknowledged as the most accurate method for evaluating kidney function, it is at present not feasible to be applied in the clinical arena. Estimated glomerular filtration rate (eGFR) is preferred due to its convenience, cost-effectiveness, and seamless integration into standard clinical practice for kidney function evaluation.

View Article and Find Full Text PDF

Background: Exogenous Cushing's syndrome, which results from prolonged glucocorticoid treatment, is associated with metabolic abnormalities. Previously, we reported the inhibitory effect of tonsil-derived mesenchymal stem cell conditioned medium (T-MSC CM) on glucocorticoid signal transduction. In this study, we investigated the therapeutic efficacy of T-MSCs in a mouse model of exogenous Cushing's syndrome.

View Article and Find Full Text PDF

During the harvest of Ilex paraguariensis, approximately 2-5 tons per hectare of thick stems are left on the soil surface. The outer portion of these stems, referred to as the coproduct, constitutes 30% of the total residue mass. Although this coproduct has been partially characterized in terms of its phytochemical profile, its technological applications remain unexplored.

View Article and Find Full Text PDF

Background: Primary aldosteronism (PA) is the leading surgically treatable cause of hypertension, with adrenalectomy as the definitive treatment for unilateral PA (UPA). However, some patients have persistent hypertension after surgery. This study aims to identify preoperative factors affecting surgical outcomes and develop a predictive model for postoperative hypertension resolution.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!