A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Gauging force by tapping tendons? Inaccurately in the human patellar tendon. | LitMetric

Gauging force by tapping tendons? Inaccurately in the human patellar tendon.

J Biomech

Human Movement Science, Faculty of Sport Science, Ruhr University Bochum, Bochum, Germany; School of Human Movement and Nutrition Sciences, University of Queensland, Brisbane, Australia. Electronic address:

Published: August 2024

Accurately estimating in vivo tendon load non-invasively remains a major challenge in biomechanics, which might be overcome by shear-wave tensiometry. Shear-wave tensiometry measures the speed of mechanically induced tendon shear waves by skin-mounted accelerometers. To gauge the feasibility and accuracy of this novel technique, we obtained patellar tendon shear wave speeds via shear-wave tensiometry during sustained or ramp voluntary contractions of the knee extensors in two experiments (n = 8 in both). In experiment one, participants produced a constant knee extension torque of ∼ 50 Nm at five different knee joint angles (i.e. variable tendon load), which resulted in estimated patellar tendon forces between 1005 ± 6N and 1182 ± 16 N. However, wave speed squared did not correlate with estimated tendon force within participants (r(31) = -0.19, p = 0.278). In experiment two, averaged correlation coefficients between normalized wave speed squared and torque of maximal and submaximal voluntary contractions across participants ranged between r = 0.43 and r = 0.94, while the time-varying correlation between these normalized signals ranged from r = -0.99 to r = 1.00. Further, the mean absolute errors (MAEs) between normalized wave speed squared and normalized torque across participants ranged between 0.03 and 0.54, which were larger than the MAEs between normalized torque and normalized summed EMG amplitude from the superficial quadriceps muscles (0.03-0.54 versus 0.06-0.26, respectively). In conclusion, there was no simple relation between shear wave speed squared and patellar tendon load, which severely limits the feasibility of shear-wave tensiometry for accurately estimating in vivo tendon load at the knee joint.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jbiomech.2024.112254DOI Listing

Publication Analysis

Top Keywords

patellar tendon
16
tendon load
16
shear-wave tensiometry
16
wave speed
16
speed squared
16
tendon
9
accurately estimating
8
estimating vivo
8
vivo tendon
8
tendon shear
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!