A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Continuous glycemic monitoring in managing diabetes in adult patients with wolfram syndrome. | LitMetric

AI Article Synopsis

  • This study assessed the effectiveness of Continuous Glucose Monitoring (CGM) in adults with insulin-dependent diabetes due to Wolfram syndrome (WFS) compared to those with type 1 diabetes (T1D).
  • Ten adults with WFS were monitored over 14 days and showed significantly lower average glucose levels and glycemic variability than 30 matched T1D patients.
  • Results indicated that WFS patients experienced less time in high-range hyperglycemia and had more stable blood sugar levels overall, suggesting different glycemic control dynamics in WFS compared to T1D.

Article Abstract

Aims: In this study we evaluated the use of Continuous Glucose Monitoring system in adults with insulin-dependent diabetes in the course of Wolfram syndrome (WFS) in comparison to patients with type 1 diabetes (T1D).

Methods: Individuals with WFS (N = 10) used continuous glucose monitoring for 14 days and were compared with 30 patients with T1D matched using propensity score for age and diabetes duration. Glycemic variability was calculated with Glyculator 3.0.

Results: We revealed significant differences in glycemic indices between adults with Wolfram syndrome-related diabetes and matched comparison group. Patients with Wolfram syndrome presented lower mean glucose in 24-h and nighttime records [24h: 141.1 ± 30.4mg/dl (N = 10) vs 164.9 ± 31.3mg/dl (N = 30), p = 0.0427; nighttime: 136.7 ± 39.6mg/dl vs 166.2 ± 32.1mg/dl (N = 30), p = 0.0442]. Moreover, they showed lower standard deviation of sensor glucose over all periods [24h: 50.3 ± 9.2mg/dl (N = 10) vs 67.7 ± 18.7 mg/dl (N = 30), p = 0.0075; daytime: 50.8 ± 8.7mg/dl (N = 10) vs 67.4 ± 18.0mg/dl (N = 30), p = 0.0082; nighttime: 45.1 ± 14.9mg/dl (N = 10) vs 65.8 ± 23.2mg/dl (n = 30), p = 0.0119] and coefficient of variation at night [33.3 ± 5.8% (N = 10) vs 40.5 ± 8.8% (N = 30), p = 0.0210]. Additionally, WFS patients displayed lower time in high-range hyperglycemia (> 250mg/dl) across all parts of day [24h: 4.6 ± 3.8% (N = 10) vs 13.4 ± 10.5% (N = 30), p = 0.0004; daytime: 4.7 ± 3.9% (N = 10) vs 13.8 ± 11.2% (N = 30), p = 0.0005; nighttime: 4.2 ± 5.5% (N = 10) vs 12.1 ± 10.3% (N = 30), p = 0.0272].

Conclusions: Adult patients with Wolfram syndrome show lower mean blood glucose, less extreme hyperglycemia, and lower glycemic variability in comparison to patients with type 1 diabetes.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11486770PMC
http://dx.doi.org/10.1007/s00592-024-02350-wDOI Listing

Publication Analysis

Top Keywords

wolfram syndrome
16
patients wolfram
12
n = 10
9
n = 30
9
adult patients
8
continuous glucose
8
glucose monitoring
8
comparison patients
8
patients type
8
type diabetes
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!