Introduction: Intra-peritoneal onlay mesh repair (IPOM) still remains the most common approach for laparoscopic repair of small to medium sized hernias worldwide. In this study, we compare our early outcomes of an established procedure, i.e. laparoscopic IPOM plus to robotic transabdominal pre-peritoneal (rTAPP) for small to medium sized primary ventral hernia. To compare laparoscopic IPOM plus with rTAPP in terms of pain score, time to ambulate, hospital stay, time to return to work as well as the expenses.

Patients And Methods: This is a retrospective analysis of prospectively collected data at our centre between July 2021 and June 2022. Operative time including docking time was recorded. Cost analysis was done in both set of patients. Pain scores were assessed using Visual Analogue Scale (VAS) at regular intervals for up to 3 months and then at the end of 1 year. Time to ambulate, return of bowel function and return to work were documented. Any complication or recurrence during the study period was recorded.

Results: Mean operative time for IPOM plus and rTAPP groups was 59.00 and 73.55 min, respectively. Mean pain score for IPOM at 6, 12 and 24 h was 7.35, 6.81 and 5.77, while for rTAPP, it was 4.73, 3 and 2.55, respectively. VAS scores at 1 week, 1 month and 3 month also showed similar trends. Mean time to ambulate in minutes for IPOM and rTAPP group was 357.69 and 223.64, respectively. Mean hospital stay in days for IPOM and rTAPP was 2.12 and 1.18, respectively. Mean time to return to work in days was 11.77 and 8.45 for IPOM and rTAPP groups, respectively. Expenditure wise, cost of TAPP was more and statistically significant, owing to the use of robotic platform. The mean overall cost of laparoscopic IPOM plus and rTAPP in rupees was 187,177.69 and 245,174.55, respectively.

Conclusion: Robotic TAPP appears an excellent alternative to laparoscopic IPOM plus. Larger studies with long-term follow-up data are further required to reinforce it.

Download full-text PDF

Source
http://dx.doi.org/10.4103/jmas.jmas_4_24DOI Listing

Publication Analysis

Top Keywords

ipom rtapp
24
laparoscopic ipom
16
time ambulate
12
return work
12
ipom
10
intra-peritoneal onlay
8
onlay mesh
8
robotic transabdominal
8
transabdominal pre-peritoneal
8
primary ventral
8

Similar Publications

Introduction: Intra-peritoneal onlay mesh repair (IPOM) still remains the most common approach for laparoscopic repair of small to medium sized hernias worldwide. In this study, we compare our early outcomes of an established procedure, i.e.

View Article and Find Full Text PDF

Morgagni hernia (MH) is a rare diaphragmatic hernia which needs surgical repair. The conventional reconstruction involves reduction of hernia, closure of the defect and placement of an intraperitoneal onlay mesh often using robotic platform for ease of dissection and suturing the mesh (r-IPOM). We propose a novel robotic preperitoneal repair (r-TAPP) of MH in four cases and compare them with conventional r-IPOM technique.

View Article and Find Full Text PDF

Minimally invasive repair for lateral ventral hernia: tailored approach from a hernia centre at a tertiary care institution.

Hernia

April 2021

Minimally Invasive Surgical Centre, Department of Surgery, National University Hospital, National University Health System (NUHS), Level 8, NUHS Tower Block, 1E Kent Ridge Road, 119228, Singapore.

Introduction: Lateral ventral hernia (LVH) is rare and can be primary or secondary. Surgical treatment of this rare hernia type is challenging due the anatomic location and technical challenges in placement and secure anchoring of mesh.

Method: Patient demographic data, intra-operative data and post-operative outcomes on all LVH repairs performed with endo-laparoscopic and robotic approach between 2016 to 2018 were reviewed and analysed.

View Article and Find Full Text PDF

Purpose: We aim to compare short-term outcomes of robotic intraperitoneal onlay (rIPOM), transabdominal preperitoneal (rTAPP) and retromuscular (rRM) repair for uncomplicated midline primary ventral hernias (PVH) and determine risk factors associated with postoperative complications.

Methods: The three groups were compared in terms of pre-, intra-, and post-operative variables. Postoperative complications were assessed using previously validated classifications.

View Article and Find Full Text PDF

Purpose: The aim of this study was to compare perioperative results of robotic IPOM (r-IPOM) and robotic TAPP (r-TAPP) in ventral hernia repair, and to identify risk factors associated with postoperative complications.

Methods: After obtaining balanced groups with propensity score matching, the comparative analysis was performed in terms of perioperative and early outcomes. All variables were also examined in a subset analysis in patients with and without complications.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!