Background: The Internal Fixator (INFIX) is a popular method, known for its minimal invasiveness and short operation time, for treating anterior pelvic ring fractures. Studies have shown that postoperative complications may occur, including anterolateral femoral cutaneous nerve injury, the femoral nerve paralysis, and delayed fracture healing. These complications are believed to be related to surgical stimulation, an excessively long lateral end of the connecting rod, a small distance between the screw and bone surface, insufficient pre-bending of the connecting rod, and difficulties in fracture reduction.

Case Presentation: We report two unique cases of lower abdominal pseudocyst complicated with suspected infection after INFIX treatment of pelvic fractures at our trauma center. Following surgical removal of the internal fixation, resolution of the cysts was observed in both patients, and subsequent postoperative follow-up revealed the absence of any residual sequelae. These cases have not been reported in previous literature reviews.

Discussion: The lower abdominal cysts, potentially arising from the dead space created during intraoperative placement of the INFIX rod, may increase infection risk. The etiology remains uncertain, despite the presence of abnormal inflammation markers in both cases, and staphylococcus aureus found in one. These cysts were confined to the lower abdomen, not involving the internal fixation, and hence, only the INFIX was removed. Postoperative oral cefazolin treatment was successful, with resolved pseudocysts and no subsequent discomfort.

Conclusion: We report two unprecedented cases of post-INFIX abdominal cysts, with a suspected link to intraoperative dead space. Despite uncertain etiology, successful management involved INFIX removal and oral cefixime therapy. These findings necessitate further exploration into the causes and management of such complications.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11297756PMC
http://dx.doi.org/10.1186/s12891-024-07747-wDOI Listing

Publication Analysis

Top Keywords

lower abdominal
12
internal fixation
12
complicated suspected
8
suspected infection
8
infection infix
8
connecting rod
8
abdominal cysts
8
dead space
8
infix
6
cases
5

Similar Publications

Objective: The first objective is to develop a nuchal thickness reference chart. The second objective is to compare rule-based algorithms and machine learning models in predicting small-for-gestational-age infants.

Method: This retrospective study involved singleton pregnancies at University Malaya Medical Centre, Malaysia, developed a nuchal thickness chart and evaluated its predictive value for small-for-gestational-age using Malaysian and Singapore cohorts.

View Article and Find Full Text PDF

Pheochromocytoma is a rare tumor originating from the adrenal gland, characterized by the secretion of catecholamines. Due to the risk of hypertensive crises associated with catecholamine release, surgical procedures in pheochromocytoma patients are risky. In this case report, laparoscopic appendectomy for acute appendicitis in a patient who has pheochromocytoma will be presented.

View Article and Find Full Text PDF

Introduction: Compared to aortic dissection and isolated visceral artery dissection, multiple peripheral arterial dissections have not been formally reported to date. Currently, there is no well-established treatment for this condition, and large-scale studies with extensive sample data are lacking.

Case Presentation: A 56-year-old male, was provisionally diagnosed with " idiopathic multiple peripheral arterial dissections.

View Article and Find Full Text PDF

Background: Acute appendicitis is one of the most common causes of an acute abdomen among pediatric patients. The diagnosis of appendicitis is challenging due to the nonspecific presentation. Diagnosis is based on historical, physical, and serologic information as well as right lower quadrant ultrasound (RLQ US).

View Article and Find Full Text PDF

Zebrafish serve as a pivotal model for bioimaging and toxicity assessments; however, the toxicity of banana peel-derived carbon dots in zebrafish has not been previously reported. The aim of this study was to assess the toxicity of carbon dots derived from banana peel in zebrafish, focusing on two types prepared through hydrothermal and pyrolysis methods. Banana peels were synthesized using hydrothermal and pyrolysis techniques and then compared for characteristics, bioimaging ability, and toxicity in zebrafish as an animal model.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!