The two electron cyclotron emission imaging (ECEI) systems installed at adjacent ports (G and H) on the KSTAR tokamak incorporate large-aperture mm-wave optics, broadband electronics, and high speed digitization (up to 1 MSa/s) for 2D and quasi-3D visualization of MHD-scale fluid dynamics. Recently, the ECEI systems have been proved to be capable of visualization of smaller scale fluctuations albeit with a limited spatiotemporal resolution and even capable of measurement of ion cyclotron harmonic waves by direct high-speed sampling of the ECE IF signals. A four-channel prototype subsystem with a higher sampling rate up to 16 GS/s has been integrated into the G-port ECEI system, enabling the measurement of plasma waves in the GHz range in the form of modulated ECE signals and characterization of high-frequency turbulence during the evolution of pedestal. To achieve higher toroidal resolution in the turbulence measurement, the H-port ECEI system is now being upgraded to have a toroidally dual detector array of 2(toroidal) × 12(vertical) × 8(radial) channel configuration and a high-speed subsystem of 2(toroidal) × 4 channel configuration. The new mm-wave optics has been designed via beam propagation simulation, and the measured performance of the fabricated lens indicates a toroidal resolution of 8-10 cm depending on the focus position and zoom factor, allowing for the measurement of parallel wavenumber up to k‖ ∼ 0.8 cm-1.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1063/5.0219245 | DOI Listing |
Rev Sci Instrum
August 2024
Department of Physics, POSTECH, Pohang, Gyeongbuk 37673, Korea.
The two electron cyclotron emission imaging (ECEI) systems installed at adjacent ports (G and H) on the KSTAR tokamak incorporate large-aperture mm-wave optics, broadband electronics, and high speed digitization (up to 1 MSa/s) for 2D and quasi-3D visualization of MHD-scale fluid dynamics. Recently, the ECEI systems have been proved to be capable of visualization of smaller scale fluctuations albeit with a limited spatiotemporal resolution and even capable of measurement of ion cyclotron harmonic waves by direct high-speed sampling of the ECE IF signals. A four-channel prototype subsystem with a higher sampling rate up to 16 GS/s has been integrated into the G-port ECEI system, enabling the measurement of plasma waves in the GHz range in the form of modulated ECE signals and characterization of high-frequency turbulence during the evolution of pedestal.
View Article and Find Full Text PDFRev Sci Instrum
April 2021
University of California, Davis, Davis, California 95616, USA.
To efficiently determine the plasma electron density fluctuations using the MIR diagnostic technique, a 55-75 GHz 65 nm-CMOS transmitter has been developed where four separate intermediate frequency (IF) signals are up-converted, amplified, and then combined to generate an 8-tone RF output; a broadband 90 nm-CMOS receiver has also been constructed, which consists of an RF-low noise amplifier (LNA), mixer, and IF amplifier. The circuits and their corresponding modules will soon be deployed on the DIII-D and NSTX-U fusion devices. A 110-140 GHz 65 nm-CMOS receiver has also been designed, which is suitable for measuring the deep-core temperature fluctuations in the DIII-D tokamak using the electron cyclotron emission imaging diagnostic system.
View Article and Find Full Text PDFRev Sci Instrum
May 2021
University of California Davis, Davis, California 95616, USA.
Monolithic, millimeter wave "system-on-chip" technology has been employed in chip heterodyne radiometers in a newly developed Electron Cyclotron Emission Imaging (ECEI) system on the DIII-D tokamak for 2D electron temperature and fluctuation diagnostics. The system employs 20 horn-waveguide receiver modules each with customized W-band (75-110 GHz) monolithic microwave integrated circuit chips comprising a W-band low noise amplifier, a balanced mixer, a ×2 local oscillator (LO) frequency doubler, and two intermediate frequency amplifier stages in each module. Compared to previous quasi-optical ECEI arrays with Schottky mixer diodes mounted on planar antennas, the upgraded W-band array exhibits >30 dB additional gain and 20× improvement in noise temperature; an internal eight times multiplier chain is used to provide LO coupling, thereby eliminating the need for quasi-optical coupling.
View Article and Find Full Text PDFAdv Exp Med Biol
February 2021
Department of Physiology, Tohoku University Graduate School of Medicine, Sendai, Japan.
In the application of advanced neuroscience techniques including optogenetics to small awake animals, it is often necessary to restrict the animal's movements. A spherical treadmill is a beneficial option that enables virtual locomotion of body- or head-restrained small animals. Besides, it has a wide application range, including virtual reality experiments.
View Article and Find Full Text PDFRev Sci Instrum
September 2020
University of California Davis, Davis, California 95616, USA.
Monolithic, millimeter-wave "system-on-chip" (SoC) technology has been employed in heterodyne receiver integrated circuit radiometers in a newly developed Electron Cyclotron Emission Imaging (ECEI) system on the DIII-D tokamak for 2D electron temperature profile and fluctuation evolution diagnostics. A prototype module operating in the E-band (72 GHz-80 GHz) was first employed in a 2 × 10 element array that demonstrated significant improvements over the previous quasi-optical Schottky diode mixer arrays during the 2018 operational campaign of the DIII-D tokamak. For compatibility with International Thermonuclear Experimental Reactor relevant scenarios on DIII-D, the SoC ECEI system was upgraded with 20 horn-waveguide receiver modules.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!