AI Article Synopsis

  • * Following surgery to fix the fractures, he underwent an 8-12 week physical therapy program focusing on various exercises to improve movement, strength, and function.
  • * Significant improvements were observed in pain, range of motion, muscle strength, and overall function due to early mobilization and a customized rehabilitation plan.

Article Abstract

This case report details the rehabilitation procedure for a 35-year-old man involved in a vehicle accident that resulted in multiple joint fractures. The patient had fractures to the proximal tibia, left bimalleolar, posterior malleolus, fourth and fifth metacarpal heads, and second and third proximal phalanges. After open reduction and internal fixation surgery, an 8-12 week physical treatment regimen was put into place. Exercises for both passive and active range of motion, isometric and progressive resistance training, and gait training were provided. The rehabilitation goals were pain relief, increased range of motion, muscle strength, flexibility, endurance, and functional independence. Pain levels, range of motion, muscle strength, and general function all significantly improved between pre- and post-rehabilitation evaluations. Early mobilization and structured physical therapy were crucial in achieving these outcomes, highlighting the importance of tailored rehabilitation protocols for post-operative recovery.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11293038PMC
http://dx.doi.org/10.7759/cureus.63654DOI Listing

Publication Analysis

Top Keywords

range motion
12
multiple joint
8
joint fractures
8
case report
8
motion muscle
8
muscle strength
8
effectiveness physiotherapy
4
rehabilitation
4
physiotherapy rehabilitation
4
rehabilitation adult
4

Similar Publications

The humeral head is the second most common anatomical site of osteonecrosis after the femoral head. Studies have reported satisfactory clinical outcomes after shoulder arthroplasty to treat osteonecrosis of the humeral head (ONHH). However, there are concerns regarding implant longevity in relatively young patients.

View Article and Find Full Text PDF

Plate tectonics is a unique feature of Earth, but its proposed time of initiation is still controversial, with published estimates ranging from ca. 4.2 to 0.

View Article and Find Full Text PDF

Impact of blood flow restriction intensity on pain perception and muscle recovery post-eccentric exercise.

Clin Physiol Funct Imaging

January 2025

Faculty of Health Sciences, Division of Physiotherapy and Rehabilitation, Istanbul Okan University, Istanbul, Turkey.

Background: Delayed onset muscle soreness (DOMS) is a well-established phenomenon characterized by ultrastructural muscle damage that typically develops following unfamiliar or high-intensity exercise. DOMS manifests with a constellation of symptoms, including muscle tenderness, stiffness, edema, mechanical hyperalgesia, and a reduced range of joint motion. In recent years, the application of blood flow restriction (BFR) has garnered attention for its potential impact on DOMS.

View Article and Find Full Text PDF

A liquid crystal elastomer (LCE) actuator capable of colorimetric humidity sensing is realized. The designed LCE features acid protonated amino azobenzene side groups in its structure, which endow the actuator with the hygroscopicity and act as the humidity reporter via color changes. Given that the protonated and deprotonated chromophore absorb visible light at different wavelengths, when the protonated LCE is under higher humidity, it absorbs more water that deprotonates azobenzene and leads to a change in color.

View Article and Find Full Text PDF

Facile Preparation of Carbon Nanotube-Based Skin-Like Pressure Sensors.

Small

December 2024

Department of Chemistry & Chemical Biology and the Brockhouse Institute for Materials Research, McMaster University, 1280 Main St. W., Hamilton, ON, L8S 4M1, Canada.

Flexible sensors have garnered significant interest for their potential to monitor human activities and provide valuable feedback for healthcare purposes. Single-walled carbon nanotubes (SWNTs) are promising materials for these applications but suffer from issues of poor purity and solubility. Dispersing SWNTs with conjugated polymers (CPs) enhances solution processability, yet the polymer sidechains can insulate the SWNTs, limiting the sensor's operating voltage.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!