A novel fixation system for a hand-held dynamometer (HHD) was designed to enable isometric muscle measurements on various muscle groups of strong, healthy individuals in a field setting. The objective of this study was to evaluate the intra- and interrater reliability of the system and determine its suitability for use by multiple researchers within large-scale data collections during field activities. Four researchers tested eight healthy subjects, who each completed eight different maximal isometric muscle strength assessments using the HHD fixation system. Intraclass correlation coefficients (ICC) results were evaluated with a 95% confidence interval. ICC results for interrater reliability demonstrated excellent agreement of all eight measurements tested. ICC results for intrarater reliability demonstrated excellent agreement for six out of eight measurements. This system provides a new opportunity for several different high-quality maximal muscle strength measurements to be collected by multiple data collectors on large numbers of strong, healthy individuals in a field setting.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11369342PMC
http://dx.doi.org/10.1002/ejsc.12148DOI Listing

Publication Analysis

Top Keywords

interrater reliability
12
isometric muscle
12
fixation system
12
intra- interrater
8
novel fixation
8
system hand-held
8
hand-held dynamometer
8
strong healthy
8
healthy individuals
8
individuals field
8

Similar Publications

Bullet characterization using Photon-Counting detector CT: A phantom study with intact bullets.

Eur J Radiol

December 2024

Department of Radiology and Nuclear Medicine, Maastricht University Medical Centre+, PO Box 5800, 6202 AZ Maastricht, the Netherlands; Mental Health and Sciences (MHeNs) Research Institute, Maastricht University, PO Box 616, 6200 MD Maastricht, the Netherlands.

Objectives: Photon-counting detector CT (PCD-CT) is expected to substantially improve and expand CT-imaging applicability due to its intrinsic spectral capabilities, increased spatial resolution, reduced electronic noise, and improved image contrast. The current study aim is to evaluate PCD-CT efficacy in characterizing bullets based on their dimensions, shape, and material composition.

Materials And Methods: This is an observational phantom study examining 11 unfired, intact bullets of various common calibers, placed in ballistic gelatin.

View Article and Find Full Text PDF

Background: Despite the increasing integration of competency-based education in medicine, there remains a significant gap in effectively assessing educational outcomes, underscoring the urgent need for designed assessment blueprints that accurately reflect both curriculum content and competency standards in Community Medicine for undergraduate students. This study, conducted across the All-India Institute of Medical Sciences (AIIMS) network, develops a summative assessment blueprint aimed at standardizing evaluations in medical education across diverse geographic locations in India.

Methods: Twenty-five experts from 10 All India Institutes of Medical Science were invited via email and contributed for summative assessment for a theory paper.

View Article and Find Full Text PDF

Human imagination has garnered growing interest in many fields. However, it remains unclear how to characterize different forms of imaginative thinking and how imagination differs between young and older adults. Here, we introduce a novel scoring protocol based on recent theoretical developments in the cognitive neuroscience of imagination to provide a broad tool with which to characterize imaginative thinking.

View Article and Find Full Text PDF

Objective: Periventricular anastomosis (PA), a recently recognized cause of hemorrhage in moyamoya disease, is reducible after bypass surgery. The timing of the reduction, however, remains poorly understood. The objectives of the present study were to demonstrate radiological reduction of PA occurring within 48 hours after surgery and to identify factors associated with reduction.

View Article and Find Full Text PDF

Background: To intraindividually compare the diagnostic performance of positron emission computed tomography (F-18-FDG-PET/CT) and diffusion-weighted magnetic resonance imaging (DW-MRI) in a non-inferiority design for the discrimination of peripheral nerve sheath tumours as benign (BPNST), atypical (ANF), or malignant (MPNST) in patients with neurofibromatosis type 1 (NF1).

Results: In this prospective single-centre study, thirty-four NF1 patients (18 male; 30 ± 11 years) underwent F-18-FDG-PET/CT and multi-b-value DW-MRI (11 b-values 0 - 800 s/mm²) at 3T. Sixty-six lesions corresponding to 39 BPNST, 11 ANF, and 16 MPNST were evaluated.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!