A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Core-shell magnetic covalent organic polymer nanocomposites as an adsorbent for the extraction of flavonoids. | LitMetric

A novel 3D magnetic nanocomposite material based on covalent organic polymers was successfully synthesized and utilized as an efficient sorbent for magnetic solid-phase extraction. It exhibited a regular core-shell structure, large specific surface area, superior stability, and paramagnetism. To evaluate its extraction efficiency, six flavonoids were tested, demonstrating maximum adsorption capacities ranging from 90 to 218 mg/g. Additionally, the material exhibited remarkable reusability and mechanical stability, maintaining its original state over eight cycles with consistent recovery. An analytical strategy combining magnetic solid-phase extraction with high performance liquid chromatography and tandem mass spectrometry was developed for the determination of flavonoids in orange, honey, soybean, and Dioscorea bulbifera L. samples. The low limits of detection (0.01-0.1 ng/mL) and limits of quantification (0.05-0.5 ng/mL), as well as satisfactory recovery (80.4-114.8%), were obtained. The linear range started from the limits of quantification to 500 ng/mL with R ≥ 0.9929. These results suggest that the prepared adsorbent possesses excellent adsorption capabilities for flavonoids, highlighting its significant potential for detecting these compounds in complex sample matrices.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00604-024-06588-7DOI Listing

Publication Analysis

Top Keywords

covalent organic
8
magnetic solid-phase
8
solid-phase extraction
8
core-shell magnetic
4
magnetic covalent
4
organic polymer
4
polymer nanocomposites
4
nanocomposites adsorbent
4
extraction
4
adsorbent extraction
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!