A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Identifying divertor detachment using a machine learning model trained on divertor camera images from DIII-D. | LitMetric

Identifying divertor detachment using a machine learning model trained on divertor camera images from DIII-D.

Rev Sci Instrum

Lawrence Livermore National Laboratory, Livermore, California 94550, USA.

Published: August 2024

This paper describes the application of a machine learning (ML) algorithm using a convolution neural network, first developed in Boyer et al. ["Classification and prediction of detachment in DIII-D using neural networks trained on C III imaging," Nucl. Fusion (submitted) (2024)], to detect divertor detachment in DIII-D. Detachment detection is based on images from tangentially viewing upper and lower filtered divertor cameras that measure CIII emission at 465 nm. Separate ML models are developed for lower single null and upper single null configurations with mostly closed divertor shapes. Due to the viewing angle and divertor geometry, camera images of the upper divertor show a stark contrast in CIII emission between attached and detached conditions and the model identified detachment with 100% accuracy in the test dataset. For the lower divertor images, the contrast between attached and detached conditions is lower and the model identifies detachment with 96% accuracy. This ML model will be applied to the image data after each shot to provide a rapid assessment of divertor detachment to aid operation of DIII-D with the potential extension to other devices in the future.

Download full-text PDF

Source
http://dx.doi.org/10.1063/5.0218724DOI Listing

Publication Analysis

Top Keywords

divertor detachment
12
machine learning
8
divertor
8
camera images
8
detachment diii-d
8
ciii emission
8
single null
8
attached detached
8
detached conditions
8
detachment
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!