Purpose: To review our initial experience with proton-based SBRT to evaluate the planning outcomes and initial patient tolerance of treatment.
Patients And Methods: From Sep. 2019 to Dec. 2020, 52 patients were treated with proton SBRT to 62 lesions. Fractionation varied by indication and site with a median of 5 fractions and median fractional dose of 8 Gy. Planning outcomes, including plan heterogeneity, conformity, and PTV volume receiving 100% of the prescription dose (PTV V100%) were evaluated. Acute toxicities were prospectively recorded, and patient reported outcomes were assessed prior to and at completion of treatment using the MD Anderson Symptom Inventory (MDASI) and EQ-5D5L visual analogue score (VAS).
Results: All treated patients completed their course of proton-based SBRT. The mean conformity index was 1.05 (range 0.51-1.48). R50% values were comparable to ideal photon parameters. PTV V100% was 89.9% on average (40.44% - 99.76%). 5 patients (10%) required plan modification due to setup or tumor changes. No patients developed a new grade 3 or greater toxicity during treatment. Comparing pretreatment to end of treatment timepoints, there was a significant improvement in the mean VAS (65 to 75, p = 0.014), with no significant change in the mean MDASI symptom (1.7, 1.8; p = 0.79) or interference (2.3, 2.4; p = 0.452) scores.
Conclusion: Proton-based SBRT can achieve dosimetric goals required by major clinical photon trials. It was well-tolerated with no decrement in patient reported outcomes and a mean 10-point improvement in VAS at the conclusion of SBRT. Further follow-up is necessary for tumor control and late effects analysis.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11288653 | PMC |
Clin Oncol (R Coll Radiol)
January 2025
Department of Radiation Oncology, Cancer Center, West China Hospital, Sichuan University, Chengdu, Sichuan 610041, China; Department of Radiotherapy Physics & Technology, West China Hospital, Sichuan University, Chengdu, Sichuan 610041, China.
Aims: To assess the robustness of 4D-optimised IMPT and PAT plans against interplay effects in non-small cell lung cancer (NSCLC) patients with respiratory motion over 10 mm, and to provide insights into the use of proton-based stereotactic body radiotherapy (SBRT) for lung cancer with significant tumour movement.
Materials And Methods: Fourteen patients with early-stage NSCLC and tumour motion >10 mm were selected. Three hypofraction regimens were generated using 4D robust optimisation with the IMPT and PAT techniques.
J Radiosurg SBRT
January 2024
Department of Radiation Oncology, Winship Cancer Institute of Emory University, Atlanta, GA, USA.
Purpose: To review our initial experience with proton-based SBRT to evaluate the planning outcomes and initial patient tolerance of treatment.
Patients And Methods: From Sep. 2019 to Dec.
Phys Med Biol
October 2021
Department of Oncology, Aarhus University Hospital, Aarhus, Denmark.
Compared to x-ray-based stereotactic body radiotherapy (SBRT) of liver cancer, proton SBRT may reduce the normal liver tissue dose. For an optimal trade-off between target and liver dose, a non-uniform dose prescription is often applied in x-ray SBRT, but lacks investigation for proton SBRT. Also, proton SBRT is prone to breathing-induced motion-uncertainties causing target mishit or dose alterations by interplay with the proton delivery.
View Article and Find Full Text PDFJ Appl Clin Med Phys
July 2021
Centre for Medical Radiation Physics (CMRP), University of Wollongong, Wollongong, New South Wales, Australia.
Purpose: The purpose of the current study was threefold: (a) investigate the impact of the variations (errors) in spot sizes in robustly optimized pencil beam scanning (PBS) proton-based stereotactic body radiation therapy (SBRT) lung plans, (b) evaluate the impact of spot sizes and position errors simultaneously, and (c) assess the overall effect of spot size and position errors occurring simultaneously in conjunction with either setup or range errors.
Methods: In this retrospective study, computed tomography (CT) data set of five lung patients was selected. Treatment plans were regenerated for a total dose of 5000 cGy(RBE) in 5 fractions using a single-field optimization (SFO) technique.
Biomed Phys Eng Express
May 2021
Centre for Medical Radiation Physics (CMRP), University of Wollongong, Wollongong, NSW, Australia.
. The purpose of the current study was to investigate the impact of RayStation analytical pencil beam (APB) and Monte Carlo (MC) algorithms on the interplay effect in pencil beam scanning (PBS) proton-based stereotactic body radiation therapy (SBRT) lung plans..
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!