Quantitative analysis of the impurities in Etimicin using hydrophilic interaction liquid chromatography coupled with charged aerosol detector.

J Pharm Biomed Anal

Key Laboratory for Core Technology of Generic Drug Evaluation National Medical Product Administration & Key laboratory of drug contacting materials quality control of zhejiang province, Zhejiang Institute for Food and Drug Control, Hangzhou 310052, China; School of Medicine, Zhejiang University, Hangzhou 310058, China. Electronic address:

Published: October 2024

Etimicin is a typical aminoglycoside antibiotic (AG). High performance liquid chromatography-evaporation light scattering detector (HPLC-ELSD) method is a commonly used method for determining impurities in Etimicin. However, due to the poor reproducibility, low sensitivity and narrow linear range of the ELSD, high-throughput quantitative analysis of impurities in Etimicin currently poses a challenge. In this study, a sensitive method using hydrophilic interaction liquid chromatography coupled with charged aerosol detector (HILIC-CAD) was developed for the analysis of the impurities in Etimicin. The liquid phase conditions for determination impurities in Etimicin were optimized using Box Behnken design (BBD) and response surface methodology (RSM), resulting in satisfactory separation and optimal CAD output signal. We also studied the influence of CAD parameters on the signal-to-noise ratio and linearity of Etimicin and its impurities. This method has also been proven to be effective in separating impurities from two other typical AGs, Isepamicin and Amikacin. In the method validation, the coefficient of determination (R) of Etimicin, Isepamicin and Amikacin and their impurities were all greater than 0.999, within the range of 0.5-50 μg/mL. The average recoveries of the impurities of three typical AGs were 99.03 %-101.22 %, RSDs all were less than 2.5 % for intra-day and inter-day precision, with good precision and accuracy. The developed HILIC-CAD quantification method was sensitive, accurate and highly selective for quantitative analysis of impurities in the AGs without need ion-pairing reagents, which is ensure the public medication safety. The method is first reported application of HILIC-CAD method for quantitative analysis of the impurities in AGs.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jpba.2024.116384DOI Listing

Publication Analysis

Top Keywords

analysis impurities
20
impurities etimicin
20
quantitative analysis
16
impurities
11
etimicin
8
hydrophilic interaction
8
interaction liquid
8
liquid chromatography
8
chromatography coupled
8
coupled charged
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!