Changes in lower limb alignment after open-wedge high tibial osteotomy (owHTO) influence joint kinematics. The aim of this study was to investigate the morphological and kinematic changes of the knee joint, in particular the patellofemoral joint, using a multibody simulation model. OwHTO with an open tibial wedge of 6-12 mm (1 mm intervals) was virtually performed on each of 13 three-dimensional (3D) computer-aided design models (CAD models) derived from computer tomography scans of full-leg cadaver specimens. For each owHTO, an individual biomechanical simulation model was built and knee flexion from 5° to 100° was simulated using a multibody simulation model of the native knee. Morphologic and alignment parameters as well as tibiofemoral and patellofemoral kinematic parameters were evaluated. Almost linear changes in tibial tuberosity trochlea groove (TT-TG) (0.42 mm/1 mm wedge height) were observed which led to pathological values (TT-TG > 20 mm) in 3 out of 13 knees. Furthermore, a 6 mm increase in osteotomy wedge height increased lateral patellofemoral rotation by 0.8° (range: 0.39° to 1.11°) and led to a lateral patellar translation of 0.8 mm (range: 0.37-3.11 mm) on average. Additionally, valgisation led to a medial translation of the tibia and a decrease in the degree of tibial internal rotation during knee flexion of approximately 0.3°/1 mm increase in osteotomy wedge height. The increase in TT-TG and the biomechanical effects observed influence patellofemoral tracking, which may increase retropatellar pressure and are potential risk factors for the development of anterior knee pain.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/jor.25945 | DOI Listing |
Sensors (Basel)
December 2024
KLEEMANN Group, 61100 Kilkis, Greece.
Timely damage detection on a mechanical system can prevent the appearance of catastrophic damage in it, as well as allow for better scheduling of its maintenance and repair process. For this purpose, multiple signal analysis methods have been developed to help identify anomalies in a system, through quantities such as vibrations or deformations in its critical components. In most applications, however, these data may be scarce or inexistent, hindering the overall process.
View Article and Find Full Text PDFBioengineering (Basel)
November 2024
Department of Materials and Production, Aalborg University, 9220 Aalborg, Denmark.
Optimization procedures provide ligament parameters by minimizing the difference between experimental measurements and computational simulations. Literature values are used as initial guesses of ligament parameters for these optimization procedures. However, it remains unknown how these values affect the estimation of ligament parameters.
View Article and Find Full Text PDFJ Chem Phys
December 2024
Department of Chemical Engineering, University of California, Santa Barbara, California 93106, USA.
Field-theoretic simulations are numerical methods for polymer field theory, which include fluctuation corrections beyond the mean-field level, successfully capturing various mesoscopic phenomena. Most field-theoretic simulations of polymeric fluids use the auxiliary field (AF) theory framework, which employs Hubbard-Stratonovich transformations for the particle-to-field conversion. Nonetheless, the Hubbard-Stratonovich transformation imposes significant limitations on the functional form of the non-bonded potentials.
View Article and Find Full Text PDFPLoS One
December 2024
College of Mechanical and Electrical Engineering, Zhoukou Normal University, Zhoukou, China.
In order to investigate the dynamic characteristics and fatigue life of the roadheader's gyration platform during the cutting process, the calculation of the cutting head load was achieved based on the force and its transformation of cutting pick, and the transient loads in the two lateral swing directions of the roadheader were calculated. Subsequently, the simulated load was applied to the multi-body model of the cutting section, and dynamic simulations were conducted. Critical information, including stress and strain distribution, as well as the maximum stress on the gyration platform, was extracted from these simulations.
View Article and Find Full Text PDFBioinspir Biomim
December 2024
Biorobotics Laboratory, Department of Computer Science and Engineering, University of South Florida, Tampa, FL, United States of America.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!