A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Negative impact of face masks in patients with interstitial lung disease: A prospective study. | LitMetric

Introduction: Face masks increase airway resistance, data on the actual extent of this effect are scarce. The aim of this study was to assess the effect of different mask types on clinical parameters during moderate exercise in healthy non-smokers, active smokers and patients with interstitial lung disease (ILD) without the need of oxygen therapy.

Methods: In a prospective observational pilot study participants performed a six-minute walk test without mask, with a surgical mask, a well-fitted FFP2 mask and with a valved FFP3 mask. Respiratory rate, blood pressure, heart rate, blood gas analysis parameters, dyspnoea and six-minute walk distance were measured. Data were analysed in an ANOVA model.

Results: 21 healthy participants, 17 active smokers without known pulmonary disease and 15 patients with interstitial lung disease were included. Participants with ILD had a significant lower walking distance, a higher respiratory rate and a lower pO when using FFP2 masks, but not with valved FFP3 masks or surgical masks compared to not wearing a mask.

Conclusion: For patients with ILD without the need of oxygen therapy wearing an FFP2 mask had a negative impact on pO, respiratory rate and walking distance in the six-minute walk test. This effect was not seen with valved FFP3 masks or surgical masks.

Download full-text PDF

Source
http://dx.doi.org/10.1055/a-2361-4723DOI Listing

Publication Analysis

Top Keywords

patients interstitial
12
interstitial lung
12
lung disease
12
six-minute walk
12
valved ffp3
12
respiratory rate
12
negative impact
8
face masks
8
active smokers
8
ild oxygen
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!