In the search of innovative methods within radiation dosimetry to provide solutions to the high demanding modern ionizing radiation applications, this work proposes an original approach to combine microorganisms and gel dosimetry characteristics by adapting biotechnology and molecular biology procedures. The design of bacterial culture media and the evaluation of viability as systems for radiation dosimetry are reported. In preliminary assessments, a highly promising dose-response has been observed for samples stored at 4 °C, displaying a linear trend within the investigated dose range. This underscores a promising performance, indicating the potential utility of the system as a radiation dosimeter.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.apradiso.2024.111455 | DOI Listing |
J Comput Assist Tomogr
January 2025
Department of Radiology, College of Medicine, University of Florida, Gainesville, FL.
Purpose: This study evaluated beam quality and radiation dosimetry of a CT scanner equipped with a novel detector and filtration technology called PureVision Optics (PVO). PVO features miniaturized electronics, a detector cut with microblade technology, and increased filtration in order to increase x-ray detection and reduce image noise.
Methods: We assessed the performance of two similar 320-detector CT scanners: one equipped with PVO and one without.
Sci Rep
January 2025
Radiation Safety and Quality Assurance division, National Cancer Center Hospital East, Chiba, 277-8577, Japan.
The impact of three-dimensional (3D) dose delivery accuracy of C-arm linacs on the planning target volume (PTV) margin was evaluated for non-coplanar intracranial stereotactic radiosurgery (SRS). A multi-institutional 3D starshot test using beams from seven directions was conducted at 22 clinics using Varian and Elekta linacs with X-ray CT-based polymer gel dosimeters. Variability in dose delivery accuracy was observed, with the distance between the imaging isocenter and each beam exceeding 1 mm at one institution for Varian and nine institutions for Elekta.
View Article and Find Full Text PDFHealth Phys
January 2025
Department of Radiation Oncology & Medical Physics, Inova Health Systems, Fairfax, Virginia.
Occupational radiation dosimeters that return high readings cannot always be explained by circumstances in the workplace. For this experiment, a series of optically stimulated luminescence (OSL) dosimeters were brought to airports to estimate the radiation dose OSLs would receive should a worker accidentally bring their dosimeter with them during travel. The OSLs returned readings between 0.
View Article and Find Full Text PDFLife Sci Space Res (Amst)
February 2025
Institute of Biomedical Problems of the Russian Academy of Sciences, 76A Khoroshevskoye shosse, 123007, Moscow, Russian Federation.
One of the most problematic goals for radiation safety during spaceflight is an assessment of additional doses received by astronauts during extravehicular activity (EVA). The Pille-ISS thermoluminescent dosimeter developed by the predecessor of the Hungarian Research Network (HUN-REN) Centre for Energy Research (Budapest, Hungary) is designed for the routine dose measurements not only inside the spacecraft compartments, but also for personal dosimetric control for EVA. During almost two decades of the International Space Station (ISS) operation, the unique set of 131 EVA doses were recorded in different conditions, such as: solar activity, ISS trajectory along the South Atlantic Anomaly (SAA), and shielding conditions provided by two kinds of spacesuits: the Extravehicular Mobility Unit (EMU) and Orlan.
View Article and Find Full Text PDFLife Sci Space Res (Amst)
February 2025
NASA Ames Research Center, Moffett Field, CA 94035, United States.
The BioSentinel CubeSat was deployed on the Artemis-I mission in November 2022 and has been continuously transmitting physical measurements of the space radiation environment since that time. Just before mission launch, we published computational model predictions of the galactic cosmic ray exposure expected inside BioSentinel for multiple locations and configurations. The predictions utilized models for the ambient galactic cosmic ray environment, radiation physics and transport, and BioSentinel geometry.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!