Introduction: Low-cost, accurate high-risk HPV tests are needed for cervical cancer screening in limited-resource settings.
Objective: To compare the performance of the low-cost Hybribio-H13 test with the Hybrid Capture® 2 to detect cervical intraepithelial neoplasia grade 2 or 3 (CIN2 and CIN3).
Materials And Methods: Archived baseline samples tested by the Hybrid Capture® 2 from women of the ASCUS-COL trial, aged 20 to 69 years, with biopsy-colposcopy directed diagnosis of CIN2+ (n = 143), CIN3+ (n = 51), and < CIN2 (n = 632) were blindly tested by the Hybribio-H13 test.
Results: The relative sensitivity of the Hybribio-H13 test versus the Hybrid Capture® 2 for detecting CIN2+ was 0.89 (90% CI = 0,80-0,98; NIT = 0,66), and for CIN3+ was 0,92 (90% CI = 0,85-0,98; NIT = 0,35). Relative specificity was 1.19 (90% CI = 1.05-1.33; NIT <0.00001). In the analysis restricted to women older than 30 years, the relative sensitivity of the Hybribio-H13 for CIN3+ was marginally below unity (ratio = 0.97; 90% CI = 0.95-0.99), and the specificity remained higher than the Hybrid Capture® 2 test.
Conclusion: The Hybribio-H13 test was as specific as the Hybrid Capture® 2 for detecting CIN2+ or CIN3+ but less sensitive. Considering these results and the young age of the population recruited for screening because of ASCUS cytology, we suggest our results warrant the evaluation of the Hybribio-H13 for screening cervical cancer, especially in the evaluated population.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11361703 | PMC |
http://dx.doi.org/10.7705/biomedica.7061 | DOI Listing |
Proc Natl Acad Sci U S A
January 2025
Department of Physiology and Biophysical Sciences, State University of New York at Buffalo, Buffalo, NY 14214.
Ion channels are generally allosteric proteins, involving specialized stimulus sensor domains conformationally linked to the gate to drive channel opening. Temperature receptors are a group of ion channels from the transient receptor potential family. They exhibit an unprecedentedly strong temperature dependence and are responsible for temperature sensing in mammals.
View Article and Find Full Text PDFProc Natl Acad Sci U S A
January 2025
Department of Chemistry, Chemical Theory Center, University of Minnesota, Minneapolis, MN 55455-0431.
Multiconfiguration pair-density functional theory (MC-PDFT) was proposed a decade ago, but it is still in the early stage of density functional development. MC-PDFT uses functionals that are called on-top functionals; they depend on the density and the on-top pair density. Most MC-PDFT calculations to date have been unoptimized translations of generalized gradient approximations (GGAs) of Kohn-Sham density functional theory (KS-DFT).
View Article and Find Full Text PDFJ Neurosurg Spine
January 2025
15Department of Neurological Surgery, University of California, San Francisco, California.
Objective: The goal of this study was to compare the impact of using a lower thoracic (LT) versus upper lumbar (UL) level as the upper instrumented vertebra (UIV) on clinical and radiographic outcomes following minimally invasive surgery for adult spinal deformity.
Methods: A multicenter retrospective study design was used. Inclusion criteria were age ≥ 18 years, and one of the following: coronal Cobb angle > 20°, sagittal vertical axis > 50 mm, pelvic tilt > 20°, pelvic incidence-lumbar lordosis mismatch > 10°.
PLoS One
January 2025
Escuela de Ingeniería Química, Pontificia Universidad Católica de Valparaíso, Valparaíso, Chile.
In this comprehensive analysis of Chile's air quality dynamics spanning 2016 to 2021, the utilization of data from the National Air Quality Information System (SINCA) and its network of monitoring stations was undertaken. Quintero, Puchuncaví, and Coyhaique were the focal points of this study, with the primary objective being the construction of predictive models for sulfur dioxide (SO2), fine particulate matter (PM2.5), and coarse particulate matter (PM10).
View Article and Find Full Text PDFPLoS One
January 2025
Medical Image Processing Research Group (MIPRG), Dept. of Elect. & Comp. Engineering, COMSATS University Islamabad, Islamabad, Pakistan.
Recovering diagnostic-quality cardiac MR images from highly under-sampled data is a current research focus, particularly in addressing cardiac and respiratory motion. Techniques such as Compressed Sensing (CS) and Parallel Imaging (pMRI) have been proposed to accelerate MRI data acquisition and improve image quality. However, these methods have limitations in high spatial-resolution applications, often resulting in blurring or residual artifacts.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!