AI Article Synopsis

  • Current research indicates that knowledge about how PFAS (per- and polyfluoroalkyl substances) behave in urban stormwater biofilter systems is lacking.
  • Various PFAS chemicals were frequently detected in both bioretention media and forebay sediments, with unknown PFAS precursors being found in even higher concentrations than known ones.
  • There is no clear relationship between PFAS concentrations and the depth of the filter media, suggesting that solely relying on shallow biofilters may not be effective for managing stormwater PFAS contamination.

Article Abstract

Current knowledge about the fate and transport behaviors of per- and polyfluoroalkyl substances (PFASs) in urban stormwater biofilter facilities is very limited. C5-14,16 perfluoroalkyl carboxylic acids [perfluorinated carboxylic acids (PFCAs)], C4,8,10 perfluoroalkanesulfonic acids (PFSAs), methyl-perfluorooctane sulfonamide acetic acid (MeFOSAA, a PFSA precursor), and unknown C6-8 PFCA and perfluorooctanesulfonic acid precursors were frequently found in bioretention media and forebay sediments at ΣPFAS concentrations of <0.03-19 and 0.064-16 μg/kg-DW, respectively. Unknown C6-8 PFCA precursor concentrations were up to ten times higher than the corresponding PFCAs, especially at forebays and biofilters' top layer. No significant trend could be attributed to PFAS and precursor concentrations versus depth of filter media, though PFAS concentrations were 2-3 times higher in the upper layers on average (significant difference between the upper (0-5 cm) and deepest (35-50 cm) layer). PFASs had a similar spatial concentration distribution in each filter media (no clear difference between short- and long-chain PFASs). Commercial land use and organic matter were important factors explaining the concentration variations among the biofilters and between the sampling depths, respectively. Given the comparable PFAS accumulations in deeper and superficial layers and possible increased mobility after precursor biotransformation, designing shallow-depth, nonamended sand biofilters or maintaining only the top layer may be insufficient for stormwater PFAS management.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11325539PMC
http://dx.doi.org/10.1021/acs.est.4c05170DOI Listing

Publication Analysis

Top Keywords

carboxylic acids
8
occurrence concentration
4
concentration distribution
4
distribution pfass
4
pfass precursors
4
precursors retained
4
retained stormwater
4
stormwater biofilters
4
biofilters current
4
current knowledge
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!