A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Quick Assessment of the Lower Limit of Cerebral Autoregulation Using Transcranial Doppler during Cardiopulmonary Bypass in Cardiac Surgery: A Feasibility Study. | LitMetric

Background: During cardiac surgery, maintaining a mean arterial pressure (MAP) within the range of cerebral autoregulation (CA) may prevent postoperative morbidity. The lower limit of cerebral autoregulation (LLA) can be determined using the mean velocity index (Mx). The standard Mx is averaged over a ten second period ( ) while using a two second averaging period ( ) is faster and may record more rapid variations in LLA. The objective of this study is to compare a quick determination of LLA (qLLA) using with the reference LLA (rLLA) using .

Methods: Single center, retrospective, observational study. Patients undergoing cardiac surgery with cardiopulmonary bypass. From January 2020 to April 2021, perioperative transcranial doppler measuring cerebral artery velocity was placed on cardiac surgery patients in order to correlate with continuous MAP values. Calculation of each patient's Mx was manually determined after the surgery and qLLA and rLLA were then calculated using a threshold value of Mx 0.4.

Results: 55 patients were included. qLLA was found in 78% of the cases versus 47% for rLLA. Despite a -3 mmHg mean bias, limits of agreement were large [-19 mmHg (95% CI: -13; -25), and +13 mmHg (95% CI: +6; +19)]. There was an important interobserver variability (kappa rLLA = 0.46; 95% CI: 0.24-0.66; and Kappa qLLA = 0.36; 95% CI: 0.20-0.52).

Conclusions: Calculation of qLLA is feasible. However, the large limits of agreement and significant interobserver variability prevent any clinical utility or interchangeability with rLLA.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11264067PMC
http://dx.doi.org/10.31083/j.rcm2406156DOI Listing

Publication Analysis

Top Keywords

cardiac surgery
16
cerebral autoregulation
12
lower limit
8
limit cerebral
8
transcranial doppler
8
cardiopulmonary bypass
8
limits agreement
8
mmhg 95%
8
interobserver variability
8
surgery
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!