A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Left Atrial Electrophysiological Properties after Pulmonary Vein Isolation Predict the Recurrence of Atrial Fibrillation: A Cohort Study. | LitMetric

Left Atrial Electrophysiological Properties after Pulmonary Vein Isolation Predict the Recurrence of Atrial Fibrillation: A Cohort Study.

Rev Cardiovasc Med

Tianjin Key Laboratory of Ionic-Molecular Function of Cardiovascular Disease, Department of Cardiology, Tianjin Institute of Cardiology, The Second Hospital of Tianjin Medical University, 300211 Tianjin, China.

Published: May 2024

Background: The aim of this work was to investigate left atrial electrophysiological properties for their ability to predict the recurrence of atrial fibrillation (AF) following pulmonary vein isolation (PVI).

Methods: The study comprised 53 patients with AF [62 (interquartile range (IQR): 52-68) years old; 47.2% females]. High-density, three-dimensional electro-anatomic mapping using PentaRay was conducted during sinus rhythm in the left atrium (LA) immediately after PVI. LA conduction time, conduction velocity in predefined anterior and posterior routes, low voltage area percentage and distribution were assessed.

Results: The AF recurrence group had longer LA conduction time compared to the non-recurrence group [11 (IQR: 10-12) ms vs. 9 (IQR: 8-10) ms, = 0.001). The percent low voltage area was greater in the recurrence group than the non-recurrence group [31.2 (IRQ: 7.1-49.3)% vs. 7.7 (IQR: 4.3-15.2)%, = 0.008]. Multivariate Cox regression revealed that LA conduction time independently predicted AF recurrence following ablation over a median follow-up of 235 days [IQR: 154-382 days; hazard ratio (HR): 2.37, 95% confidence interval (CI): 1.08-5.23, = 0.031]. The optimal cut-off for LA conduction time was 98 ms [area under curve (AUC): 0.926, sensitivity: 0.833, specificity: 0.894, 0.01]. Kaplan-Meier analysis revealed that patients with a conduction time 98 ms had a higher rate of AF recurrence following ablation ( 0.001).

Conclusions: Patients with longer LA conduction time after PVI had more frequent AF recurrence.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11267206PMC
http://dx.doi.org/10.31083/j.rcm2505167DOI Listing

Publication Analysis

Top Keywords

conduction time
24
left atrial
8
atrial electrophysiological
8
electrophysiological properties
8
pulmonary vein
8
vein isolation
8
predict recurrence
8
recurrence atrial
8
atrial fibrillation
8
low voltage
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!