Objective: One proposed method to improve sound localisation for bilateral cochlear implant (BiCI) users is to synchronise the automatic gain control (AGC) of both audio processors. In this study we tested whether AGC synchronisation in a dual-loop front-end processing scheme with a 3:1 compression ratio improves sound localisation acuity.

Design: Source identification in the frontal hemifield was tested in in an anechoic chamber as a function of (roving) presentation level. Three different methods of AGC synchronisation were compared to the standard unsynchronised approach. Both root mean square error (RMSE) and signed bias were calculated to evaluate sound localisation in the horizontal plane.

Study Sample: Six BiCI users.

Results: None of the three AGC synchronisation methods yielded significant improvements in either localisation error or bias, neither across presentation levels nor for individual presentation levels. For synchronised AGC, the pooled mean (standard deviation) localisation error of the three synchronisation methods was 24.7 (5.8) degrees RMSE, for unsynchronised AGC it was 27.4 (7.5) degrees. The localisation bias was 5.1 (5.5) degrees for synchronised AGC and 5.0 (3.8) for unsynchronised.

Conclusions: These findings do not support the hypothesis that the tested AGC synchronisation configurations improves localisation acuity in bilateral users of MED-EL cochlear implants.

Download full-text PDF

Source
http://dx.doi.org/10.1080/14992027.2024.2383700DOI Listing

Publication Analysis

Top Keywords

sound localisation
16
agc synchronisation
16
localisation
8
automatic gain
8
bilateral cochlear
8
cochlear implant
8
agc
8
tested agc
8
synchronisation methods
8
localisation error
8

Similar Publications

Middle Ear Mechanics in the Barn Owl.

J Morphol

January 2025

Department of Zoology, Denver Museum of Nature & Science, Denver, Colorado, USA.

The barn owl is a common research subject in auditory science due to its exceptional capacity for high frequency hearing and superb sound source localization capabilities. Despite longstanding interest in the auditory performance of barn owls, the function of its middle ear has attracted remarkably little attention. Here, we report the middle ear transfer function measured by laser Doppler vibrometry and direct measurements of inner ear pressures.

View Article and Find Full Text PDF

Clinical Manifestations.

Alzheimers Dement

December 2024

Dementia Research Centre, UCL Queen Square Institute of Neurology, University College London, London, United Kingdom.

Background: Patients with behavioural variant frontotemporal dementia (bvFTD) and right temporal variant frontotemporal dementia (rtvFTD) commonly exhibit abnormal hedonic and other behavioural responses to sounds, however hearing dysfunction in this disorder is poorly characterised. Here we addressed this issue using the Queen Square Tests of Auditory Cognition (QSTAC) - a neuropsychological battery for the systematic assessment of central auditory functions (including pitch pattern perception, environmental sound recognition, sound localisation and emotion processing) in cognitively impaired people.

Method: The QSTAC was administered to 12 patients with bvFTD, 7 patients with rtvFTD and 24 patients with comparator dementia syndromes (primary progressive aphasia and typical Alzheimer's disease) and 15 healthy age-matched individuals.

View Article and Find Full Text PDF

The effect of right versus left long-term single-sided deafness on sound source localization.

J Otol

July 2024

Department of Otolaryngology Head and Neck Surgery, Chinese PLA General Hospital, Chinese PLA Medical School, Beijing, 100853, China.

Purpose: To analyze the effect of right versus left long-term single-sided deafness (SSD) on sound source localization (SSL), discuss the necessity of intervention and treatment for SSD patients, and analyze the therapeutic effect of long-term unilateral cochlear implantation (UCI) from the perspective of SSL.

Methods: This study included 25 patients with SSD, 11 patients with UCI, and 30 participants with normal hearing (NH). Their SSL ability was tested by obtaining their average root mean square (RMS) error values of SSL test.

View Article and Find Full Text PDF

Audiological performance and subjective satisfaction of the ADHEAR system in experienced pediatric users with unilateral microtia and aural atresia.

Int J Pediatr Otorhinolaryngol

December 2024

Division of Otology, Department of Otorhinolaryngology & Head and Neck Surgery, Linkou Chang Gung Memorial Hospital, Taoyuan, Taiwan; School of Medicine, Chang Gung University, Taoyuan, Taiwan. Electronic address:

Introduction: Despite the reported auditory deficits and developmental challenges in children with unilateral microtia and aural atresia (UMAA), there remains a lack of consensus on early intervention with bone conduction hearing aids (BCHAs) to restore binaural hearing due to the uncertain clinical benefits and intolerability of the conventional devices. Previous studies investigating the auditory benefits under binaural hearing condition were limited and demonstrated controversial opinions in heterogenous patient groups with various devices. Our study aimed to evaluate the audiological performance, including monoaural and binaural hearing, and subjective satisfaction of the ADHEAR system, a novel adhesive BCHA, in experienced pediatric users with UMAA.

View Article and Find Full Text PDF

Objective: Aim: To improve the effectiveness of surgical treatment for patients with post-traumatic tympanic membrane perforations and concurrent Eustachian tube dysfunction through simultaneous combined surgical methods.

Patients And Methods: Materials and Methods: We analyzed clinical and functional outcomes of 35 patients (mean age: 34 ± 10,5 years) with tympanic membrane perforations caused by acoustic and blast injuries. The patients were divided into two groups: the first group (n=17) underwent only tympanoplasty type 1, while the second group (n=18) underwent simultaneous septoplasty, inferior turbinectomy, and tympanoplasty with prolonged middle ear ventilation using a subanular Silverstein tube.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!