Background: Venous sinus stenosis can be associated with cerebrovascular disorders. Understanding the role of blood flow disturbances in these disorders is often hampered by the lack of patient-specific flow rates. Our goal was to demonstrate the impact of this by predicting individual flow rates retrospectively from routine manometry and angiography.

Methods: Ten cases, spanning a range of stenosis severities and pressure gradients, were selected from a cohort of patients who had undergone venous stenting for pulsatile tinnitus. Lumen geometries were digitally segmented from CT venograms. A simplified Bernoulli formula was derived to estimate individual cycle-average flow rates from clinical pressure gradients and minimum lumen cross-section areas. High-fidelity pulsatile computational fluid dynamics (CFD) simulations were performed to compare predictions of flow disturbances using generic versus individual flow rates, and to validate the Bernoulli formula.

Results: Individual flow rates derived from the Bernoulli formula deviated by up to 47% from the assumed generic flow rate, resulting in substantial differences in CFD predictions of post-stenotic flow instabilities. Pressure gradients estimated by the simplified Bernoulli formula were, however, highly predictive of pressure gradients from the full CFD simulations (R=0.95; slope=0.98, 95% CI 0.88 to 1.09).

Conclusions: A simple Bernoulli formula can predict CFD-estimated trans-stenotic pressure gradients in realistic venous geometries. As demonstrated here, this may be used to recover individual flow rates from routine-but-invasive clinical measurements; however, it also suggests a simpler path towards non-invasive estimation of trans-stenotic pressure gradients that may avoid some of the challenges associated with 4D flow MRI approaches.

Download full-text PDF

Source
http://dx.doi.org/10.1136/jnis-2024-022074DOI Listing

Publication Analysis

Top Keywords

pressure gradients
28
flow rates
28
individual flow
16
bernoulli formula
16
trans-stenotic pressure
12
flow
12
flow disturbances
8
simplified bernoulli
8
cfd simulations
8
pressure
7

Similar Publications

The compliant nature of cerebral blood vessels may represent an important mechanical protection for sustained cerebral perfusion during reductions in arterial blood pressure (ABP). However, whether the rise in cerebrovascular compliance (Ci) with falling ABP persists and exhibits a threshold effect remains unknown. Therefore, we analyzed Ci changes during graded head-up tilt (HUT) in individuals with autonomic failure (AF), a group that tolerates graded and progressive reductions in ABP.

View Article and Find Full Text PDF

Detection of functional diversity gradients and their geoclimatic filters is sensitive to data types (occurrence vs. abundance) and spatial scales (sites vs. regions).

Plant Divers

November 2024

Laboratório de Ciências Ambientais, Universidade Estadual do Norte Fluminense Darcy Ribeiro, Campos dos Goytacazes, Rio de Janeiro, Brazil.

Functional diversity (FD) reflects within- and between-site variation of species traits (α- and β-FD, respectively). Understanding how much data types (occurrence-based vs. abundance-weighted) and spatial scales (sites vs.

View Article and Find Full Text PDF

Tight sandstone gas reservoirs are characterized by high water saturation, significant seepage resistance, low single-well productivity, rapid decline, and low gas recovery. Enhancing the recovery rate of tight sandstone gas reservoirs is a complex engineering challenge that necessitates thorough, refined, and systematic research into its fundamental theories. This study employs a comprehensive approach integrating mercury injection, nuclear magnetic resonance, micro-model visualization, and simulation experiments of displacement and inter-layer seepage flow, alongside foundational seepage theories, to systematically explore the characteristics of tight sandstone gas reservoirs, seepage patterns, and methods for improving gas recovery.

View Article and Find Full Text PDF

Background: Repair of the regurgitant bicuspid aortic valve is an attractive alternative to valve replacement. Although good long-term outcomes have been reported, postoperative aortic stenosis remains a major late cause of repair failure in bicuspid aortic valves. Sinus plication is effective for creating a more symmetrical commissural angle, leading to a decrease in the mean transvalvular pressure gradient.

View Article and Find Full Text PDF

Purpose: This study aimed to assess the hemodynamic changes in the vena cava and predict the likelihood of Cardiac Remodeling (CR) and Myocardial Fibrosis (MF) in athletes utilizing four-dimensional (4D) parameters.

Materials And Methods: A total of 108 athletes and 29 healthy sedentary controls were prospectively recruited and underwent Cardiac Magnetic Resonance (CMR) scanning. The 4D flow parameters, including both general and advanced parameters of four planes for the Superior Vena Cava (SVC) and Inferior Vena Cava (IVC) (sheets 1-4), were measured and compared between the different groups.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!