Purpose: To compare the effectiveness of 2 track sealing techniques following computed tomography (CT)-guided lung biopsy using either gelatin sponge slurry (GSS) or saline to reduce the rate of postbiopsy pneumothorax.

Materials And Methods: In this prospective study, a total of 266 patients (median age, 66.2 years; range, 25.5-89.2 years; 150 men) were included between July 2019 and January 2023. The patients referred for a CT-guided lung biopsy, in whom the needle would pass through aerated lung, were randomly assigned to either the GSS sealing technique group (n = 132) or the saline track sealing technique (n = 134) in a 1:1 ratio. All biopsies were performed using a 19-gauge coaxial needle in a tertiary hospital by 1 of 4 interventional radiologists with varying levels of experience (F.C., L.G., P.L., C.V.). The outcomes were pneumothorax occurrence, pneumothorax-related intervention (simple aspiration and/or drainage), and biopsy-related hospital stay length.

Results: Pneumothorax rates were 12.1% in the GSS group and 24.6% in the saline group (P = .008). Hospital length of stay was significantly shorter in the GSS group (P = .003). The need for pneumothorax-related intervention did not reach statistical significance between the groups (6.8% vs 12.7%; P = .107). In the multiple logistic regression analysis, track sealing with GSS was a protective factor for pneumothorax (odds ratio [OR], 0.44; 95% CI, 0.22-0.87; P = .019), and emphysema was associated with higher risk of pneumothorax (OR, 2.67; 95% CI, 1.31-5.44; P = .007).

Conclusions: Track sealing with GSS following a CT-guided lung biopsy is significantly more effective than saline in reducing postbiopsy pneumothorax and results in shorter hospital stay.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jvir.2024.07.019DOI Listing

Publication Analysis

Top Keywords

track sealing
20
ct-guided lung
16
lung biopsy
16
biopsy gelatin
8
gelatin sponge
8
sponge slurry
8
saline reducing
8
reducing postbiopsy
8
postbiopsy pneumothorax
8
sealing technique
8

Similar Publications

Assessment of radon level and the associated radiological risk from soil samples of quarry area at Hakim Gara, Ethiopia.

Environ Monit Assess

December 2024

School of Nuclear and Allied Sciences, University of Ghana, Atomic Campus, P.O. Box LG 80 Legon, Accra, Ghana.

Excavation of terrestrial surface of the Earth could enhance the chance of exposure to radon while gases in the underground get access to escape. This study was aimed to assess the level of radon concentration from soil samples of quarrying sites at Hakim Gara in Ethiopia using CR-39 detectors in sealed container technique. The results of the measured radon concentration level were ranging from 164.

View Article and Find Full Text PDF

In a sealed electromagnetic relay, the change in the surface roughness mainly depends on the collision wear between the contact and the moving reed and the ablation effect of the arc on the contact surface based on the strong correlation between the contact resistance and the surface roughness of the Ag-Mg-Ni contact. With a change in contact resistance, the contact temperature increase in a hermetically sealed electromagnetic relay (HSER) is greatly affected. Under extreme overload conditions, the contact surface is severely ablated by the arc, and the roughness increases rapidly with the number of cycles, which greatly affects the contact resistance of the contact surface and the reliability of the relay.

View Article and Find Full Text PDF

Parameters to Improve the Accuracy of Intraoral Scanners for Fabricating Tooth-Supported Restorations.

J Esthet Restor Dent

November 2024

Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, Washington, USA.

Objectives: To review the factors that impact the accuracy of intraoral scanners (IOSs) when fabricating tooth-supported restorations.

Overview: Factors can have a different impact on IOS accuracy depending on the scanning purpose. If the goal is to fabricate tooth-supported restorations, it is essential to review the following operator-related factors: IOS technology and system, scan extension and starting quadrant, scanning pattern, scanning distance, and rescanning methods.

View Article and Find Full Text PDF

A Mem-dELISA platform for dual color and ultrasensitive digital detection of colocalized proteins on extracellular vesicles.

Biosens Bioelectron

January 2025

Department of Chemical and Biomolecular Engineering, University of Notre Dame, Notre Dame, IN, 46556, USA; Department of Aerospace and Mechanical Engineering, University of Notre Dame, Notre Dame, IN, 46556, USA. Electronic address:

Accurate, multiplex, and ultrasensitive measurement of different colocalized protein markers on individual tumor-derived extracellular vesicles (EVs) and dimerized proteins with multiple epitopes could provide insights into cancer heterogeneity, therapy management and early diagnostics that cannot be extracted from bulk methods. However, current digital protein assays lack certain features to enable robust colocalization, including multi-color detection capability, large dynamic range, and selectivity against background proteins. Here, we report a lithography-free, inexpensive (< $0.

View Article and Find Full Text PDF

Sealing the Deal: The Role of Track Cautery after Lung Ablation.

J Vasc Interv Radiol

January 2025

Departments of Biomedical Engineering and Radiology, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin. Electronic address:

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!