Polymer-metal complexes (PMCs) based on poly(2,2'-bipyridine-4,4'-dicarboxamide-co-polydimethylsiloxanes) with cyclometalated di(2-phenylpyridinato-C,N')iridium(III) fragments and cross-linked by Zn (Zn[Ir]-BipyPDMSs) or Ir (Ir[Ir]-BipyPDMSs) represent flexible, stretchable, phosphorescent, and self-healing molecular oxygen sensors. PMCs provide strong phosphorescence at λ = 595-605 nm. Zn[Ir]-BipyPDMS with PDMS chain length of M = 5000 has the highest quantum yield of 9.3% and is a molecular oxygen sensor at different O concentrations (0-100 vol%) compared to Ir[Ir]-BipyPDMSs. A Stern-Volmer constant is determined for Zn[Ir]-BipyPDMS as K = 0.014%, which is similar to the reported oxygen-sensitive iridium(III) complexes. All synthesized PMCs exhibit high elongation at break (up to 1100%) and self-healing efficiency (up to 99%).

Download full-text PDF

Source
http://dx.doi.org/10.1002/marc.202400450DOI Listing

Publication Analysis

Top Keywords

oxygen sensors
8
molecular oxygen
8
iridiumiii-incorporating self-healing
4
self-healing polysiloxanes
4
polysiloxanes materials
4
materials light-emitting
4
light-emitting oxygen
4
sensors polymer-metal
4
polymer-metal complexes
4
complexes pmcs
4

Similar Publications

Radical covalent organic frameworks (RCOFs) have demonstrated significant potential in redox catalysis and energy conversion applications. However, the synthesis of stable RCOFs with well-defined neutral carbon radical centers is challenging due to the inherent radical instability, limited synthetic methods and characterization difficulties. Building upon the understanding of stable carbon radicals and structural modulations for preparing crystalline COFs, herein we report the synthesis of a crystalline carbon-centered RCOF through a facile post-oxidation process.

View Article and Find Full Text PDF

Validation of Aerobic Capacity (VO2max) and Pulse Oximetry in Wearable Technology.

Sensors (Basel)

January 2025

School of Integrated Health Sciences, Department of Kinesiology and Nutrition Sciences, University of Nevada, Las Vegas, NV 89154, USA.

Introduction: As wearable technology becomes increasingly popular and sophisticated, independent validation is needed to determine its accuracy and potential applications. Therefore, the purpose of this study was to evaluate the accuracy (validity) of VO2max estimates and blood oxygen saturation measured via pulse oximetry using the Garmin fēnix 6 with a general population participant pool.

Methods: We recruited apparently healthy individuals (both active and sedentary) for VO2max (n = 19) and pulse oximetry testing (n = 22).

View Article and Find Full Text PDF

Temperature Dependence on Microstructure, Crystallization Orientation, and Piezoelectric Properties of ZnO Films.

Sensors (Basel)

January 2025

State Key Laboratory of Materials Processing and Die & Mould Technology, School of Materials Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074, China.

This study has investigated the effects of different annealing temperatures on the microstructure, chemical composition, phase structure, and piezoelectric properties of ZnO films. The analysis focuses on how annealing temperature influences the oxygen content and the preferred c-axis (002) orientation of the films. It was found that annealing significantly increases the grain size and optimizes the columnar crystal structure, though excessive high-temperature annealing leads to structural degradation.

View Article and Find Full Text PDF

In this study, an approach has been proposed in response to the urgent need for a sensitive and stable method for glucose detection at low concentrations. Platinum octaethylporphyrin (PtOEP) was chosen as the probe and embedded into the matrix material to yield a glucose-sensing film, i.e.

View Article and Find Full Text PDF

Background Light Suppression for Multispectral Imaging in Surgical Settings.

Sensors (Basel)

December 2024

Institute of Smart Systems and Services, Pforzheim University, 75175 Pforzheim, Germany.

Multispectral imaging (MSI) enables non-invasive tissue differentiation based on spectral characteristics and has shown great potential as a tool for surgical guidance. However, adapting MSI to open surgeries is challenging. Systems that rely on light sources present in the operating room experience limitations due to frequent lighting changes, which distort the spectral data and require countermeasures such as disruptive recalibrations.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!