Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Capillary isoelectric focusing (CIEF) coupled with electrospray ionization mass spectrometry (ESI-MS) is regarded as an outstanding approach for protein and proteoform analysis, combining a high-resolution separation technique and an enhanced detection technique. The few so-far developed CIEF-ESI-MS approaches exhibit limitations regarding sensitivity and separation performance. Here, we report a new generic methodology for CIEF-ESI-MS based on chemical mobilization, leading to highly efficient separation. This new integrated methodology relies on exchanging catholyte, initially introduced in the nanoCEasy interface in the focusing step, with sheath liquid (SL) in order to chemically mobilize the analytes into the ESI-MS system. The CIEF-MS method is evaluated by separation of a peptide set, model proteins, and monoclonal antibody charge variants. The effect of various parameters including master mixture composition, field strength, catholyte, SL composition, focusing time, and capillary conditions is optimized and discussed. Excellent separation performance can be achieved with a pI resolution down to 0.1 pH unit. The mobilization reproducibility is demonstrated with "migration time" RSDs below 10%. Additionally, the chemical mobilization is compared with the pressure assistance-chemical mobilization method, demonstrating that even a small pressure causes a strong decrease in separation performance, which clearly indicates the benefit of the chemical mobilization-based method. The applicability and separation power of the developed method are further exhibited by separation of Fc-conjugated insulins (mass = 62 kDa) differing in only one amino acid.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/acs.analchem.4c02441 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!