A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Safety and efficacy of the mAXIS stapes prosthesis. | LitMetric

Safety and efficacy of the mAXIS stapes prosthesis.

Eur Arch Otorhinolaryngol

Department of Otorhinolaryngology, Head and Neck Surgery, Nicholas Bevis, University Medical Center Goettingen, Robert-Koch- Straße 40, 37075, Goettingen, Germany.

Published: December 2024

Purpose: Otosclerosis leads to a fixed stapes footplate and thus to hearing loss. The predominant treatment method is surgery, with various types of stapes prostheses available. The aim of this study was to investigate the safety and efficacy of the new mAXIS Stapes Prosthesis.

Methods: 34 cases of otosclerosis were implanted with the new mAXIS Stapes Prosthesis. Comprehensive clinical assessments, including pre- and postoperative pure tone audiometry was performed at short-term (ST) follow-up at 25 (± 15) days and mid-term (MT) follow-up at 181 (± 107) days. The pure tone average of 0.5, 1, 2 and 3 kHz (PTA4) was calculated.

Results: In all cases, the application of the prosthesis was successful and straightforward. The postoperative PTA4 air-bone gap was 10.7 ± 5.2 dB at ST follow-up (n = 34) and 8.3 ± 4.1 dB at MT follow-up (n = 18). In 61% of cases, the ABG-closure was within 10 dB and in 100% of cases within 20 dB at MT follow-up.

Conclusion: Findings of this study support that the mAXIS Stapes Prosthesis is safe for implantation and shows promising audiological outcome. Future investigations will contribute its long-term efficacy and safety profile.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11564318PMC
http://dx.doi.org/10.1007/s00405-024-08854-zDOI Listing

Publication Analysis

Top Keywords

maxis stapes
16
stapes prosthesis
12
safety efficacy
8
efficacy maxis
8
pure tone
8
stapes
6
maxis
4
prosthesis
4
prosthesis purpose
4
purpose otosclerosis
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!