Introduction: The aim of this 11-year retrospective multicentric study is to evaluate the policy of 14 maxillofacial surgery divisions in terms of titanium plate removal from paediatric patients who had undergone open reduction and internal fixation (ORIF) to treat maxillofacial fractures.

Material And Methods: Patients ≤ 16 years undergoing surgical treatment for fractures of middle and lower third of the face between January 2011 and December 2022, with a minimum follow-up of 6 months, were included. Age (group A: ≤ 6 years, B: 7-12 years, C: 13-16 years), sex, fracture location and type, surgical approach, number, and location of positioned and removed plates, timing and indications for removal were recorded.

Results: 191/383 (50 %) patients (median age, 10 years; M:F ratio 2.1:1) underwent removal of 319/708 (45 %) plates. Maxillary dentoalveolar process (91 %), angle/ramus (63 %) and mandibular body (61 %) had a significantly higher removal rate than other fracture sites (p < 0.001). A significant decreasing trend in removal with increasing age was observed, from 83 % in Group A to 24 % in Group C (p < 0.001). On the total of positioned plates, 11 % were removed for symptomatic reasons (5 % infections, 6 % discomfort/pain) and 34 % for other reasons (28 % scheduled removal).

Discussion: This multicentric study showed that plate removal was not performed routinely in the paediatric population. The incidence and causes of symptomatic plates removal were consistent with the literature, while the plate removal rate from asymptomatic patients was lower. A correlation was found between increasing age and a reduction in the frequency of plate removal procedures.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jormas.2024.101986DOI Listing

Publication Analysis

Top Keywords

plate removal
16
removal
10
plates removal
8
internal fixation
8
multicentric study
8
≤ years
8
removal rate
8
increasing age
8
maxillofacial
5
plates
5

Similar Publications

The culture of A549 cells and its secreted cytokine IL-6 monitoring on the designed multifunctional microfluidic chip.

Talanta

December 2024

Key Disciplines Lab of Novel Micro-Nano Devices and System Technology, Key Laboratory of Optoelectronic Technology and Systems, Ministry of Education, Chongqing University, Shapingba, Chongqing, 400044, China; School of Optoelectronics Engineering, Chongqing University, Shapingba, Chongqing, 400044, China. Electronic address:

A multifunctional microfluidic chip integrated with perfusion cell culture and in situ SERS detection of cell secretion was designed and developed for the detection of IL-6 secretion from LPS-stimulation of A549 cells in this paper. Researching works were focused on A549 cell activity and secretion in the constructed LPS-stimulated A549 cells model. On the designed microchip, a bubble trap chamber was designed to remove the bubbles in the culture medium which could also be simultaneously preheated by a split hot plate.

View Article and Find Full Text PDF

Diatom biosilica for liquid chromatography.

J Chromatogr A

December 2024

Nicolaus Copernicus University in Toruń, Interdisciplinary Centre of Modern Technologies, Wileńska 4, 87-100, Toruń, Poland; Nicolaus Copernicus University in Toruń, Faculty of Chemistry, Department of Environmental Chemistry and Bioanalytics, Gagarina 7, PL-87-100 Toruń, Poland; Prof. Jan Czochralski Kuyavian-Pomeranian Research & Development Centre, Krasińskiego Str. 4, 87-100 Toruń, Poland. Electronic address:

This work presents, for the first time, the preparation method and subsequent use of biosilica in column liquid chromatography in reverse-phase mode. Diatom biosilica consists of the siliceous exoskeletons (frustules) of unicellular algae. Controlled cultivation of Pseudostaurosira trainorii diatoms resulted in frustules with an average diameter of approximately 4 µm, sidewall thickness of 1 µm, and a bottom thickness of 110-150 nm.

View Article and Find Full Text PDF

Background: Addressing hindfoot varus via calcaneal osteotomy with simultaneous peroneal tendon repair from a single incision has not been thoroughly assessed. Some concerns with one incision are wound complications, nerve damage, and symptomatic hardware.

Methods: Patients operated on by one surgeon May 2012 to January 2022 were retrospectively reviewed with minimum 2-year follow-up via in-person visit, telephone, and chart review.

View Article and Find Full Text PDF

Background: Although it is well established that antibiotic prophylaxis is not needed in soft tissue upper extremity cases, there is still no definitive consensus when hardware implantation is involved. We hypothesize that antibiotic prophylaxis is not necessary and there is no difference in postoperative surgical site infection rates regardless of preoperative antibiotic administration.

Methods: A retrospective cohort analysis was performed on upper extremity surgical cases with hardware implantation performed at a single institution amongst 5 hand surgeons between November 2021 and November 2023.

View Article and Find Full Text PDF

Background: No clear agreement exists on the degree of bone formation required to remove a metal plate without correction loss after medial opening-wedge high tibial osteotomy (MOWHTO). We aimed to investigate the mechanical stability of the proximal tibia with different bone formations after plate removal in MOWHTO using finite element models and determine the extent of bone formation when the plate can be removed without correction loss.

Methods: The MOWHTO models with 5, 10, and 15 mm opening gaps were generated.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!