A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Two-Field Excitation for Contactless Inductive Flow Tomography. | LitMetric

Two-Field Excitation for Contactless Inductive Flow Tomography.

Sensors (Basel)

Helmholtz-Zentrum Dresden-Rossendorf, Institute of Fluid Dynamics, Department Magnetohydrodynamics, Bautzner Landstraße 400, 01328 Dresden, Germany.

Published: July 2024

Contactless inductive flow tomography (CIFT) is a flow measurement technique allowing for visualization of the global flow in electrically conducting fluids. The method is based on the principle of induction by motion: very weak induced magnetic fields arise from the fluid motion under the influence of a primary excitation magnetic field and can be measured precisely outside of the fluid volume. The structure of the causative flow field can be reconstructed from the induced magnetic field values by solving the according linear inverse problem using appropriate regularization methods. The concurrent use of more than one excitation magnetic field is necessary to fully reconstruct three-dimensional liquid metal flows. In our laboratory demonstrator experiment, we impose two excitation magnetic fields perpendicular to each other to a mechanically driven flow of the liquid metal alloy GaInSn. In the first approach, the excitation fields are multiplexed. Here, the temporal resolution of the measurement needs to be kept as high as possible. Consecutive application by multiplexing enables determining the flow structure in the liquid with a temporal resolution down to 3 s with the existing equipment. In another approach, we concurrently apply two sinusoidal excitation fields with different frequencies. The signals are disentangled on the basis of the lock-in principle, enabling a successful reconstruction of the liquid metal flow.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11280805PMC
http://dx.doi.org/10.3390/s24144458DOI Listing

Publication Analysis

Top Keywords

excitation magnetic
12
magnetic field
12
liquid metal
12
contactless inductive
8
flow
8
inductive flow
8
flow tomography
8
induced magnetic
8
magnetic fields
8
excitation fields
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!