The introduction of closed-loop systems in the pediatric population has been a revolution in the management and evolution of diabetes. However, there are not many published studies in situations in which the feeding, schedules, and activities of the children deviate from the routine for which the systems were programmed, as in the case of a summer camp for children and adolescents with diabetes, where the specific programming of this device is not well known. It was a single-center prospective preliminary study. A total of twenty-seven patients (mean age 11.9 ± 1.9 years, 40% male, duration of diabetes 6.44 ± 2.83 years) were included (twenty with Medtronic MiniMed 780G system and seven with Tandem Control-IQ). Glucometric variables and pump functionality were monitored during the 7-day camp and in the following 3 weeks. There was no decrease from the objective TIR 70% at any moment. The worst results in Time Below Range were at 72 h from starting the camp, and the worst results in Time Above Range were in the first 24 h, with a progressive improvement after that. No episodes of level 3 hypoglycemia or ketoacidosis occurred. The use of specific programming in two integrated systems, with complex blood glucose regulation algorithms and not-prepared-for situations with increased levels of physical activity or abrupt changes in feeding routines, did not result in an increased risk of level 3 hypoglycemia and ketoacidosis for our pediatric type 1 diabetes (T1D) patients, regardless of the closed-loop device.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11279836 | PMC |
http://dx.doi.org/10.3390/nu16142210 | DOI Listing |
J Imaging Inform Med
January 2025
University Hospitals Cleveland Medical Center, Case Western Reserve University, 11100 Euclid Avenue, BSH 5056, Cleveland, OH, 44106, USA.
The objective of this study is to implement an actionable incidental findings (AIFs) communication workflow integrated into the electronic health record (EHR) using dictation macros to improve the quality of radiology reports and facilitate delivery of findings to clinicians. The workflow was implemented across an academic multi-hospital health system and used by over 100 radiologists from 12 divisions. Standardized macros were created for different organ systems including the thyroid, lungs, liver, pancreas, spleen, kidney, female reproductive, and others, designed based on the ACR Novel Quality Measure Set.
View Article and Find Full Text PDFJ Diabetes Res
January 2025
Diabetes Center, Dallah Hospital, Riyadh, Saudi Arabia.
The study was aimed at assessing the role of the MiniMed780G system of glycemic control before, during, and after Ramadan among people with Type 1 diabetes (PwT1D). This is a single-center retrospective analysis of MiniMed780G system users aged 14 years and above whose glycemic profiles were collected from February 21 to May 20, 2023, which corresponds to the Hijri months of Sha'ban, Ramadan, and Shawwal 1444/1445. Data was collected, processed, and analyzed in the framework of the Medtronic Galaxy service of the One Hospital Clinical Service (OHCS) program in Dallah Hospital, Riyadh, Saudi Arabia.
View Article and Find Full Text PDFSci Rep
January 2025
The Key Laboratory for Agricultural Machinery Intelligent Control and Manufacturing of Fujian Education Institutions, Wuyi University, Nanping, 354300, Fujian, China.
This paper proposes an adaptive real-time tillage depth control system for electric rotary tillers, based on Linear Active Disturbance Rejection Control (LADRC), to improve tillage depth accuracy in tea garden intercropping with soybeans. The tillage depth control system comprises a body posture sensor, a control unit, and a hybrid stepper motor, integrating sensor data to drive the motor and achieve precise depth control. Real-time displacement sensor signals are compared with target values, enabling closed-loop control of the rotary tiller.
View Article and Find Full Text PDFBackground: Simulation offers an opportunity to practice neonatal resuscitation and test clinical systems to improve safety. The authors used simulation-based clinical systems testing (SbCST) with a Healthcare Failure Mode and Effect Analysis (HFMEA) rubric to categorize and quantify latent safety threats (LSTs) during in situ training in eight rural delivery hospitals. The research team hypothesized that most LSTs would be common across hospitals.
View Article and Find Full Text PDFBMJ Open Diabetes Res Care
December 2024
The Australian Centre for Behavioural Research in Diabetes, Diabetes Victoria, Carlton, Victoria, Australia.
Introduction: This analysis aimed to investigate diabetes-specific psychological outcomes among adults with type 1 diabetes (T1D) using hybrid closed-loop (HCL) versus standard therapy.
Research Design And Methods: In this multicenter, open-label, randomized, controlled, parallel-group clinical trial, adults with T1D were allocated to 26 weeks of HCL (MiniMed™ 670G) or standard therapy (insulin pump or multiple daily injections without real-time continuous glucose monitoring). Psychological outcomes (awareness and fear of hypoglycemia; and diabetes-specific positive well-being, diabetes distress, diabetes treatment satisfaction, and diabetes-specific quality of life (QoL)) were measured at enrollment, mid-trial and end-trial.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!