A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Long-Term Outcomes and a Radiological Assessment of Hydroxyapatite-Tricalcium Phosphate-Coated Total Hip Arthroplasty (Trilogy/Zimmer): A Long-Term Follow-Up Study. | LitMetric

Favorable short- and mid-term results for hydroxyapatite (HA)-tricalcium phosphate (TCP)-coated total hip arthroplasty (THA) (Trilogy/Zimmer) have been reported in the literature; however, the long-term results beyond 15 years have not been documented. Therefore, this study evaluated the long-term postoperative results, radiological bone changes, and implant fixation of the acetabular component of HA-TCP-coated THA. This is a retrospective cohort study of 212 patients who underwent primary HA-TCP-coated THA (Trilogy/Zimmer) at our institution between 1 October 2002, and 31 March 2008; 166 who were available for follow-up at least 15 years postoperatively were included (capture rate: 78.3%). All implants were Trilogy/Zimmer. We investigated the survival rate, with aseptic loosening as the endpoint. Clinical evaluations included the presence of dislocation and a modified Harris Hip Score (mHHS) preoperatively and at the final observation. The mean age at surgery and at the follow-up period were 57.7 ± 9.6 and 17.1 ± 1.5 years, respectively. The survival rate was 99.4% (165/166), with aseptic loosening as the endpoint. Dislocation was observed in 4/166 (2.4%) patients. The mHHS improved significantly from 46.1 points preoperatively to 82.2 points during the last survey ( < 0.05). The results revealed that fixation was favorable in all cases except for one case of aseptic loosening. The Trilogy implant coated with HA-TCP was highly effective in bone induction, and bone ingrowth was considered to have occurred without failure, further indicating its usefulness. The long-term results of cementless THA using an HA-TCP coating (Trilogy/Zimmer), with a mean follow-up period of 17.1 years, revealed a commendable survival rate of 99.4%, considering aseptic loosening as the endpoint. HA-TCP-coated THA (Trilogy/Zimmer) had good long-term results. However, further long-term observation is required in patients who have undergone this surgery, and the stem side should be evaluated and investigated, including comorbidities.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11278935PMC
http://dx.doi.org/10.3390/medicina60071154DOI Listing

Publication Analysis

Top Keywords

aseptic loosening
16
tha trilogy/zimmer
12
ha-tcp-coated tha
12
survival rate
12
loosening endpoint
12
total hip
8
hip arthroplasty
8
follow-up period
8
171 years
8
rate 994%
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!